Results 91 to 100 of about 275 (147)

Viscoelasticity and Extensional Rheology of Model Cayley-Tree Polymers of Different Generations

open access: yesJournal of Rheology, 2010
We investigated the rheology of a series of anionically synthesized, model symmetric Cayley tree poly(methylmethacrylates) having from 1 to 4 generations of identical molar mass.
Savvas G Hatzikiriakos   +2 more
exaly   +2 more sources

Free Volume Distribution of Branched Poly(Methyl Methacrylates): Conformational Probes Study [PDF]

open access: yesJournal of Molecular Structure, 2016
© 2016 Elsevier B.V.In this work we studied the free volume distribution of the branched poly (methylmethacrylates) by the method of conformational probes. The freezing temperatures of the conformational transitions of the probes introduced into branched
A B Remizov
exaly   +1 more source

Stereocomplexation of Poly(Methylmethacrylates) in Monolayers at the Air Water Interface

open access: yesMakromolekulare Chemie Macromolecular Symposia, 1991
When mixtures of isotactic and syndiotactic PMMA are spread on the air water interface from a non-complexing solvent, a pressure induced transition can be observed, that is identified as a stereocomplexation between the two stereoregular components in ...
R. H. G. Brinkhuis   +3 more
exaly   +2 more sources
Some of the next articles are maybe not open access.

Related searches:

THE CARDIOVASCULAR EFFECTS OF METHYLMETHACRYLATE

Survey of Anesthesiology, 1975
The effects of the liquid component of commercial acrylic cement and of pure methylmethacrylate monomer on mean arterial blood pressure, central venous pressure, heart rate and cardiac output have been compared in a series of six anaesthetised dogs. No significant differences were found between the two substances.
R H, Ellis, J, Mulvein
openaire   +2 more sources

Methylmethacrylate Seeks an Appeal

Southern Medical Journal, 1981
We measured hemodynamic and respiratory parameters before and after applying methylmethacrylate (MMC) to acetabular and femoral sites during neuroleptanesthesia and prosthetic hip surgery. No significant major changes were documented. Previously reported adverse effects probably have been due to medullary emboli, humoral responses, or a negative action
J M, Gooding   +3 more
openaire   +2 more sources

Methylmethacrylate Hypersensitivity in Orthopaedic Surgery

Acta Orthopaedica Scandinavica, 1978
The sensitivity to methylmethacrylate monomer in 25 patients undergoing orthopaedic surgery was studied. No relation could be found between the cardiovascular reactions observed during the cementation of the femoral prosthesis and the complement system, investigated by measuring the serum concentration of the haemolytic complement, components 3 and 4.
Monteny, E.   +3 more
openaire   +3 more sources