Results 131 to 140 of about 80,246 (200)
Orchestrating Anion–π+ Interactions to Accelerate Metal‐Free Room‐Temperature Phosphorescence
Tuning anion–π+ interactions in pyridinium iodide contact ion pairs enables ultrafast metal‐free room‐temperature phosphorescence (540–605 nm) with radiative rates up to 5.2×105 s−1. Strong iodide→π+ charge‐transfer coupling, enhanced spin–orbit interactions, and dynamic ion‐pair organization accelerate intersystem crossing and emission, establishing ...
Eetu Hakkarainen +12 more
wiley +2 more sources
THE COLORIMETRY WITH A HIGH DIMENSIONAL RESOLUTION
The developed method of Objects photometric and colorimetric characteristics measurements on the base of digital cameras are described. Application of the initial samples those are realized as the support of the control points on a non-radiant Object or ...
I. E. Zuikov, E. N. Savkova
doaj
Traceability, Liability and Incentives for Food Safety and Quality [PDF]
In this paper we focus specifically on the implications for additional traceability in the context of liability for food safety problems. We model formally the linkage between traceability and food safety and establish the implications of an increase in ...
Sumner, Daniel A., Pouliot, Sebastien
core
Optimization of Fully Screen‐Printed Electrostrictive Multilayer Actuators
The impact of geometric parameters on the blocking force and the bending angle of electrostrictive P(VDF‐ter‐TrFE‐ter‐CTFE) monolayer actuators is extensively studied in order to guide their choice. The 4.7 %mol CTFE composition shows great interest in multilayer actuators.
Sara Beauquis +7 more
wiley +1 more source
Metrological traceability is fundamental to ensuring the reliability and comparability of measurements in science and industry. As measurement environments become increasingly complex—requiring multi-parameter monitoring, dynamic process control, and ...
Saxholm, Sari
core +3 more sources
ABSTRACT Low‐cost sensors are increasingly being used, and also considered for usage in regulatory contexts like air quality monitoring. Proper sensor calibration and uncertainty evaluation is necessary in such cases. With the advance of mobile sensors, for example, installed on top of a car, new test and calibration paradigms are required, in ...
Gertjan Kok, Shahin Tabandeh
wiley +1 more source
Quality in every drop: A national survey on calibration, control, and training in the use of pipettes in Norwegian medical laboratories Introduction: Good practices for calibration, control, and training in pipette use are essential to reduce ...
Solveig Mo +5 more
doaj
Excess Na treatment in DMF‐based, solution‐processed CuIn(S,Se)2 solar cell fabrication dramatically widens the process window (air‐annealing temperature after spin‐coating), enabling high efficiencies that are otherwise attainable only within a narrow temperature range.
Ivan L. Opao +18 more
wiley +1 more source
TRACEABILITY AND CERTIFICATION IN MEAT SUPPLY CHAINS [PDF]
Food safety problems such as the BSE and dioxin crises focused attention on traceability systems and the certification of such systems. This study analyzes the status and perspectives of traceability systems and certification schemes, and reviews their ...
Meuwissen, Miranda P.M. +3 more
core
A Model Based Systems Engineering Framework for Digital Twins in Medical Device Innovation
ABSTRACT Medical device development remains constrained by development processes centered largely in the physical domain. These methods limited early understanding of system behavior and prolonged timelines relative to other innovation pathways. Such limitations increase prototype cycle duration and the number of iterations required to resolve design ...
Tanguy René Pinol +3 more
wiley +1 more source