Long-term performance of a transcatheter pacing system: 12-Month results from the Micra Transcatheter Pacing Study [PDF]
Early performance of the Micra transcatheter pacemaker from the global clinical trial reported a 99.2% implant success rate, low and stable pacing capture thresholds, and a low (4.0%) rate of major complications up to 6 months.The purpose of this report was to describe the prespecified long-term safety objective of Micra at 12 months and electrical ...
Dedra Fagan
exaly +3 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Heart Rhythm, 2018
Experience with retrieval of the Micra transcatheter pacing system (TPS) is limited because of its relatively newer technology. Although abandonment of the TPS at end of life is recommended, certain situations such as endovascular infection or device embolization warrant retrieval.The purpose of this study was to report the worldwide experience with ...
Anish Amin
exaly +3 more sources
Experience with retrieval of the Micra transcatheter pacing system (TPS) is limited because of its relatively newer technology. Although abandonment of the TPS at end of life is recommended, certain situations such as endovascular infection or device embolization warrant retrieval.The purpose of this study was to report the worldwide experience with ...
Anish Amin
exaly +3 more sources
About the Micra Transcatheter Pacing System. Response
Revista Espanola De Cardiologia (English Ed ), 2016Miguel A Arias, Marta Pachón
exaly +3 more sources
Successful replacement of the longest worldwide in situ Nanostim leadless cardiac pacemaker for a Micra Transcatheter Pacing System [PDF]
Niek Beurskens, Fleur Tjong
exaly +4 more sources
Design and Evaluation of the Micra Transcatheter Pacing System for Bradyarrhythmia Management
Future Cardiology, 2018Permanent cardiac pacemakers have traditionally comprised a surgically implanted subcutaneous pulse generator affixed to at least one transvenous pacing lead. Despite technological advances, implant-related complications and transvenous-lead failure rates have remained high.
Benedict M, Wiles, Paul R, Roberts
openaire +2 more sources
About the Micra Transcatheter Pacing System
Revista Espanola De Cardiologia (English Ed ), 2016Ángel, Morales Martínez de Tejada +1 more
exaly +3 more sources
Implantation of the Micra Transcatheter Pacing System: Initial Experience in a Single Spanish Center
Revista Espanola De Cardiologia (English Ed ), 2016Miguel A Arias, Luis Rodriguez-Padial
exaly +3 more sources
Abstract 16795: Fate of Dislodged Micra Transcatheter Pacing System in Coronary Sinus
Circulation, 2020Background: Micra Transcatheter Pacing System is a leadless pacemaker for treatment of symptomatic high-grade atrioventricular block and persistent atrial fibrillation. We present a case report of dislodgement of a Micra device into the coronary sinus.
Sangeeta Prabhakar Bhat +2 more
openaire +1 more source
Heart Rhythm, 2022
Early results from the Micra investigational trial and Micra Post-Approval Registry (PAR) demonstrated excellent safety and device performance; however, outcomes based on anticoagulation (AC) status at implant have not been evaluated.The purpose of this study was to report implant characteristics, perforation rate, and vascular-related events based on ...
Jens Brock Johansen
exaly +5 more sources
Early results from the Micra investigational trial and Micra Post-Approval Registry (PAR) demonstrated excellent safety and device performance; however, outcomes based on anticoagulation (AC) status at implant have not been evaluated.The purpose of this study was to report implant characteristics, perforation rate, and vascular-related events based on ...
Jens Brock Johansen
exaly +5 more sources
Life cycle management of Micra transcatheter pacing system: Data from a high‐volume center
Journal of Cardiovascular Electrophysiology, 2020AbstractBackgroundData on the management of Micra transcatheter pacing system (TPS) at the time of an upgrade or during battery depletion is limited.ObjectiveWe sought to evaluate the management patterns of patients implanted with a Micra TPS during long‐term follow‐up.MethodsWe retrospectively identified patients who underwent Micra implantation from ...
Neal K. Bhatia +9 more
openaire +2 more sources