Results 91 to 100 of about 18,600 (239)

Ultra‐High Frequency Ultrasound Imaging and Quantification of Microvascular Flow in Xenograft Renal Cell Carcinoma in an Avian Chorioallantoic Membrane Model

open access: yesJournal of Ultrasound in Medicine, EarlyView.
Patient‐derived xenograft (PDX) tumor models initiated in avian chorioallantoic membranes (CAM) are under investigation to evaluate the effectiveness of therapeutic options with the objective of personalizing treatments. CAM PDXs paired with ultra‐high frequency ultrasound (UHFUS) imaging could potentially constitute prospective high throughput assays ...
Sara Mar   +5 more
wiley   +1 more source

Laser‐Based In Situ Diagnostics of Temperature and Material‐Growth Dynamics in Photothermal Laser Nanoprinting of ZnO

open access: yesLaser &Photonics Reviews, EarlyView.
This work elucidates the previously unknown thermal dynamics during sub‐micrometer photothermal laser printing of zinc oxide using a non‐invasive transmission‐based in situ measurement. The elevated temperatures are shown to be highly localized around the laser focal spot, reaching average temperature increases of about 113 K per mW of laser power ...
Steven Kraus   +4 more
wiley   +1 more source

Harnessing Optical Limiting in Saturable Absorbers for Reconfigurable Spectral Engineering of Ultrafast Fiber Lasers

open access: yesLaser &Photonics Reviews, EarlyView.
Optical limiting in a nanomaterial‐polymer saturable absorber is harnessed as a functional intracavity degree of freedom, where pump‐controlled photothermal loss continuously reshapes the gain spectrum of rare‐earth ions, enabling non‐mechanical spectral engineering in an ultrafast fiber laser.
Maolin Dai   +4 more
wiley   +1 more source

Mechanical Properties and Testing Strategies for Two‐Photon Lithography: A Review of Current Practices and Emerging Challenges

open access: yesLaser &Photonics Reviews, EarlyView.
Two‐photon lithography enables the fabrication of complex 3D microstructures with tunable mechanical properties spanning from soft hydrogels to rigid hybrid networks. This review summarizes how material composition, printing parameters, and post‐processing govern stiffness and viscoelasticity, highlighting advanced characterization methods and emerging
Dalila Fontana   +6 more
wiley   +1 more source

Active Electromagnetic Interference Suppression for MRI and Proton Resonance Frequency Shift Thermometry During MRI‐Guided Microwave Ablation

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To develop a software‐based active electromagnetic interference (EMI) suppression (AES) framework on whole‐body multi‐channel MRI systems for reliable MRI and MR thermometry during MRI‐guided microwave ablation (MWA). Methods In addition to primary imaging coils, an unloaded standard body array coil was positioned outside the imaging ...
Qing Dai   +5 more
wiley   +1 more source

Experimental study on oily wastewater treatment with low energy consumption based on effervescent atomizer

open access: yesGongye shui chuli
The low energy consumption and efficient treatment of oily wastewater using microbubble flotation technology is a current research hotspot. A low-energy microbubble jet flotation system for treating oily wastewater was established using an effervescent ...
LIU Liansheng   +5 more
doaj   +1 more source

Assessing and Quantifying Variability Across Vacuum‐Assisted Resin Infusion Variants for Aerospace‐Grade Composite Manufacturing

open access: yesPolymer Composites, EarlyView.
Radar‐plot comparison of consolidation quality and flexural performance of composite laminates manufactured by six vacuum‐infusion routes, evaluated at the resin‐inlet and vacuum‐port regions. ABSTRACT Conventional vacuum‐assisted resin transfer molding (C‐VARTM) is recognized as a cost‐effective resin infusion technique for manufacturing large‐scale ...
Ilhan Kahraman   +8 more
wiley   +1 more source

Microbubble‐Based Ultrasound Contrast Agents in Contrast‐Enhanced Ultrasonography for Managing Portal Hypertension in Cirrhosis

open access: yesPortal Hypertension &Cirrhosis, EarlyView.
As the hepatic venous pressure gradient (HVPG) remains the current gold standard for diagnosing portal hypertension in cirrhosis, its clinical application is limited by invasiveness, high cost, and restricted availability. Given the urgent need for noninvasive techniques to dynamically monitor portal vein pressure (PVP), contrast‐enhanced ...
Danping Huang   +5 more
wiley   +1 more source

Sono‐Vasomics With Super‐Resolution Contrast‐Enhanced Ultrasound (SR‐CEUS) for Characterization of Focal Liver Lesions: A Case Report

open access: yesPortal Hypertension &Cirrhosis, EarlyView.
ABSTRACT Accurate differentiation between benign and malignant focal liver lesions (FLLs) remains a major diagnostic challenge. Vasomics, an emerging discipline, classifies vascular phenotypes into anatomical, biomechanical, biochemical, pathophysiological, and composite categories. Sono‐Vasomics, the ultrasound‐based subset, leverages super‐resolution
Yijie Qiu   +5 more
wiley   +1 more source

Responsive nitric oxide‐releasing antibacterial materials for biofilm‐associated infections: Mechanisms, design strategies, and applications

open access: yesResponsive Materials, EarlyView.
This review summarizes the recent progress in responsive NO‐releasing materials and their applications in biofilm‐associated infectious diseases. The design principles and response mechanisms are given to provide inspiration toward the future development of multi‐responsive NO‐releasing materials.
Wenyue Sun   +8 more
wiley   +1 more source

Home - About - Disclaimer - Privacy