Results 201 to 210 of about 24,553 (255)
Some of the next articles are maybe not open access.

Intelligent pH-responsive dental sealants to prevent long-term microleakage.

Dental Materials, 2021
OBJECTIVES Microleakage is a determinant factor of failures in sealant application. In this study, DMAEM (dodecylmethylaminoethyl methacrylate), a pH-responsive antibacterial agent, was incorporated into resin-based sealant for the first time.
Hao Li   +8 more
semanticscholar   +1 more source

Microgap and bacterial microleakage during the osseointegration period: An in vitro assessment of the cover screw and healing abutment in a platform-switched implant system.

The Journal of prosthetic dentistry (Print), 2021
STATEMENT OF PROBLEM Microgap and bacterial microleakage at the implant-prosthetic abutment interface are recognized concerns for implant-supported restorations, leading to inflammation of the peri-implant tissues, with deleterious consequences for ...
P. F. Fernandes   +4 more
semanticscholar   +1 more source

Microleakage

Journal of Dentistry, 1992
A critical review of techniques used in the assessment of microleakage in dental restorations is presented. These techniques include the use of air pressure, bacteria, radioisotopes, electrochemistry, chemical tracers and dye penetration. Wide variations in methodologies are revealed.
M J, Taylor, E, Lynch
openaire   +2 more sources

In vitro assessment of PEEK and titanium implant abutments: Screw loosening and microleakage evaluations under dynamic mechanical testing.

The Journal of prosthetic dentistry (Print), 2020
STATEMENT OF PROBLEM Polyetheretherketone (PEEK) has been advocated to replace metal components in dentistry. Although PEEK is a high-performance polymer with a white color, adequate biological response, and resistance to fracture, data to support PEEK ...
J. Ortega-Martínez   +6 more
semanticscholar   +1 more source

Microleakage of root restorations

The Journal of the American Dental Association, 1988
This study evaluated the microleakage of various restorative materials placed in root surfaces. A minimum of 20 freshly extracted single-rooted teeth were used for each combination of restorative materials. Four preparations were made on the root surface and each restored with a different material.
K K, Wenner   +4 more
openaire   +2 more sources

Microleakage of Resected MTA

Journal of Endodontics, 2002
Forty-six single rooted extracted human teeth were used in this study. After cleaning and shaping, twenty canals were randomly selected for obturation with MTA placed in an orthograde manor (Group 1). Another twenty roots were obturated with gutta-percha and Kerr EWT sealer, using warm vertical compaction (Group 2). The apical 3 mm of each root in both
Wallis E, Andelin   +4 more
openaire   +2 more sources

Microleakage and enamel finish

The Journal of Prosthetic Dentistry, 1978
Cavity preparations that are finished with hand instruments allow significantly less marginal leakage than those which are completed only with rotary instruments. This does not mean that hand-instruments walls are perfectly smooth; it only means that these walls allow less marginal leakage.
S C, Khera, K C, Chan
openaire   +2 more sources

Microleakage of retrograde amalgams

Journal of Endodontics, 1985
In this two-part in vitro investigation, apical leakage was electrochemically analyzed in teeth with different thicknesses and compositions of dental amalgam. In part 1, the apices of 10 teeth each were filled with zinc-containing amalgam to a depth of 1 mm or 3 mm.
G D, Mattison   +3 more
openaire   +2 more sources

Microleakage : a review

Journal of Dentistry, 1976
Abstract Microleakage may be defined as the passage of bacteria, fluids, molecules or ions between a cavity wall and the restorative material applied to it. Many techniques have been devised to test the cavity-sealing properties of restorations both in vitro and in vivo .
openaire   +2 more sources

Microleakage of indirect composite inlays

Dental Materials, 1989
The purpose of this in vitro study was to evaluate the microleakage of indirect composite inlays and to compare leakage of inlays with directly placed composite restorations. Standardized MOD preparations were cut in 50 extracted human molars. One gingival margin was placed in enamel above the CEJ, and the other was placed in dentin below the CEJ.
E A, Hasegawa, D B, Boyer, D C, Chan
openaire   +2 more sources

Home - About - Disclaimer - Privacy