Tailoring Functional Properties of Ti–Ni–Cu Shape Memory Alloy Thin Films for MEMS Actuators
A comprehensive study of critical parameters required to develop well‐performing Ti–Ni–Cu thin film shape memory alloy microactuators is provided. Materials science and device integration aspects are integrated by addressing structural and physical relationships using complementary characterization techniques as well as a practical fabrication solution
Elaheh Akbarnejad +6 more
wiley +1 more source
FPGA-based reconfigurable scanning and data acquisition system for scanning electron microscopy. [PDF]
Gong K, Kim J, Kim BG, Cho B.
europepmc +1 more source
A Lightweight Procedural Layer for Hybrid Experimental–Computational Workflows in Materials Science
We unveil a prototype hybrid‐workflow framework that fuses automatedcomputation with hands‐on experiments. Built atop pyiron, a lightweight, parameterized layer translates procedure descriptions into executable manual steps, syncing instrument settings, human interventions, and data capture in real‐time today.
Steffen Brinckmann +8 more
wiley +1 more source
Cryo-FIB Lift-Out and Electron Tomography Workflow for Bacteria-Nanopillar Interface Imaging Under Native Conditions: Investigating Dragonfly Inspired Bactericidal Titanium Surfaces. [PDF]
Bandara CD +7 more
europepmc +1 more source
Creep‐Induced Microstructural Evolution in an A2‐B2 Superalloy
A 27.3Ta‐27.3Mo‐27.3Ti‐8Cr‐10Al (at.%) refractory high‐entropy alloy with precipitation‐strengthened A2‐B2 microstructure was studied by creep tests at 1030°C, which demonstrate a transition in deformation mechanisms in the range of 100–150 MPa applied stress. This is associated with changes in dislocation–precipitate interactions. Relevant deformation
Liu Yang +10 more
wiley +1 more source
Mitigation of artifacts in imaging biosamples with optical scanning transmission electron microscopy. [PDF]
Kievits AJ +4 more
europepmc +1 more source
Influence of Test Temperature and Test Frequency on Fatigue Life of Aluminum Alloy EN AW‐2618A
The influence of test temperature and test frequency on the fatigue life of EN AW‐2618A is investigated. High‐cycle fatigue tests are performed at different test temperatures and frequencies on the 1000 h/230°C overaged state. Both test parameters reduce fatigue life due to time‐dependent damage mechanisms.
Ying Han +5 more
wiley +1 more source
Analytical electron tomography, fine structure EELS and nanoscale X-ray CT of nanoporous Copper materials [PDF]
Kormilina Tatiana +5 more
doaj +1 more source
Morphological description of the tongue of the Boa constrictor. [PDF]
Gonçalves TC +5 more
europepmc +1 more source

