Results 251 to 260 of about 31,470 (289)
Some of the next articles are maybe not open access.

Microtome Sections of Charcoal: – Technical Note –

IAWA Journal, 2012
This note describes and illustrates a rapid and user-friendly method to section fragile charcoals by microtome after applying two component adhesive to the transverse charcoal surface and using adhesive tape to prevent the sections to disintegrate.
openaire   +1 more source

The counting of cells and nuclei in microtome sections

Journal of Cell Science, 1962
ABSTRACT A quantitative relation between the number of nuclei in a tissue and the number of nuclear fragments in its resultant microtome sections has been established by a new method. The general nature of the argument suggested that the correction procedure, although previously restricted to nuclei bounded by membranes, could be applied
openaire   +1 more source

Section thickness is identical for the sliding microtome and rotary microtome under the continuous cooling device condition

Acta Histochemica
To date, no report has compared section thickness (ST) between the sliding microtome (SM) and rotary microtome (RM). We used the ice pack (IP) condition, in which the paraffin block was not cooled during slicing, and a continuous cooling device (CCD) for continuous cooling during slicing.
Mayuna Fukuzawa   +7 more
openaire   +2 more sources

An Improved Clinical Microtome for Sectioning Frozen Tissue

Stain Technology, 1951
(1951). An Improved Clinical Microtome for Sectioning Frozen Tissue. Stain Technology: Vol. 26, No. 2, pp. 137-138.
Robert T. White, Ruth A. Allen
openaire   +1 more source

Holding plastic-embedded specimens for sectioning in a rotary microtome

Experientia, 1976
Three methods are evaluated for holding capsules of plastic-embedded tissue for rotary microtomy. Use of a V-block is rapid but deforms the capsule. Gluing the capsule to a supporting block is useful for reorientation of the capsule but otherwise time consuming. adapter is easy to use, does not deform the tissue, and is the preferred method for routine
openaire   +2 more sources

Contributions to Semithin Sextioning on A Conventional Rotary Microtome

Stain Technology, 1979
Procedures for obtaining sections 1 micrometer thick on a conventional rotary microtome are described. Hydrophilic resin blocks with adequate hardness and elasticity for semithin sectioning are made by addition of divinylbenzene and methylmethacrylate to a commercial embedding kit.
openaire   +2 more sources

Use of the Microtome Cryostat for Rapid Frozen Sections

American Journal of Clinical Pathology, 1961
R M, NUNNALLY, J P, ABBOTT
openaire   +2 more sources

Fabric Embedding for Microtome Sectioning

Textile Research Journal, 1955
openaire   +1 more source

Home - About - Disclaimer - Privacy