This paper discusses test results concerning flow boiling heat transfer in a minichannel 1.7 mm in depth, 16 mm in width and 180 mm in length. The essential part of the experimental stand was a vertically oriented rectangular minichannel, which was ...
Strąk Kinga, Piasecka Magdalena
doaj +1 more source
Comparison of various flow maldistribution quantification methods in mini heat exchangers. [PDF]
Dąbrowski P.
europepmc +1 more source
Effects of two-phase flow friction factor correlations on the optimal pressure drop-martinelli parameter pair in a mini-channel [PDF]
Substantial research has been completed with more on-going on the flow pattern and heat transfer associated with two-phase flows. Discrepancies reported may have been as much as agreements, due to the different models, approaches, flow regimes ...
Ahmad, Robiah +3 more
core
Heat transfer in minichannels and microchannels CPU cooling systems [PDF]
A CPU functioning is extremely complex and it was experimentally revealed that a direct dependence between working speed and cooling degree exists. When the contact between two surfaces is imperfect, the specific thermal resistance of interface layer suddenly increases, so it became of frequent use to apply diverse materials between the CPU and ...
openaire +3 more sources
The paper presents the results of investigations of flow velocity field distribution downstream of the nanofibrous filter in a minichannel determined by the particle image velocimetry (PIV) method.
Andrzej Krupa +3 more
doaj +1 more source
Comparison of heat transfer in straight and corrugated minichannels with two-phase flow
Measurements of heat transfer rates performed with an experimental condensation heat exchanger are reported for a corrugated minichannel tube and for a straight minichannel tube. The two cases were compared at same flow regimes.
Peukert P., Hrubý J.
doaj +1 more source
Quench front progression in a superheated porous medium: experimental analysis and model development [PDF]
In case of severe accident in a nuclear reactor, the fuel rods may be highly damaged and oxidized and finally collapse to form a debris bed. Removal of decay heat from a debris bed is a challenging issue because of the difficulty for water to flow inside.
Bachrata, Andrea +4 more
core
Flow condensation heat transfer coefficient and pressure drop data for R134a alternative refrigerants R513A and R450A in a 0.95-mm-diameter minichannel. [PDF]
Morrow JA, Derby MM.
europepmc +1 more source
This study investigated FC-72 boiling heat transfer in minichannels using two non-contact temperature measurement techniques: liquid crystal thermography (LCT) and infrared thermography (IRT).
Magdalena Piasecka +2 more
doaj +1 more source
Saturated flow boiling in small- to micro- diameter metallic tubes: Experimental results and modeling [PDF]
Some results of a long-term study of flow boiling patterns, heat transfer rates and pressure drop of R134a at pressures of 6-14 bar in five vertical stainless steel tubes of internal diameter 4.26, 2.88, 2.01, 1.1 and 0.52 mm are presented in this paper.
Karayiannis, TG +2 more
core