Results 81 to 90 of about 2,849 (213)
Nonsurgical Correction of Brodie Bite in Mixed Dentition Using Quad‐Helix Expansion: A Case Report
ABSTRACT This case report presents a nonsurgical correction of a dentoalveolar Brodie bite in a mixed dentition patient using a quad‐helix appliance. Mandibular expansion resolved the transverse discrepancy within 3 months, improving occlusion, and eliminating a habitual mandibular shift that had contributed to facial asymmetry.
Kazem Dalaei +2 more
wiley +1 more source
Objectives: To demonstrate how class II malocclusion can be corrected with the aid of miniscrews, without the patient's cooperation, by exploiting the growth differential to improve skeletal relationships.
PERILLO, Letizia +3 more
core +1 more source
The effect of rotation moment on the stability of immediately loaded orthodontic miniscrews: a pilot study. [PDF]
The aim of this study was to evaluate the effect of the direction and magnitude of the rotation moment to loaded orthodontic miniscrews on stability.
차정열, 황충주
core +1 more source
Posterior crossbite and mandibular asymmetry affect esthetics and function. We report treatment of 3 patients with posterior crossbite with mandibular asymmetry but different anteroposterior and vertical characteristics.
Fukawa, R +7 more
core +1 more source
A concurrent finite‐element framework is presented for the design of a patient‐specific AZ31B sub‐orbital osteosynthesis implant manufactured by superplastic forming. The approach couples process simulation and biomechanical analysis to quantify the effects of thickness heterogeneity and grain‐growth‐induced strength degradation.
Antonio Piccininni +5 more
wiley +1 more source
Biological Effects of Anodic Oxidation on Titanium Miniscrews: An In Vitro Study on Human Cells
This controlled in vitro study compared the effects of varying the thickness of a TiO2 layer on cellular activity using commercially available miniscrew samples with identical surface features to derive information with direct clinical impact.
Giorgio Iodice +4 more
doaj +1 more source
ABSTRACT Objective The use of narrow‐diameter implants has emerged as a strategy to compensate for the reduced bone dimensions of maxillary lateral incisor agenesis (MLIA). This study integrates finite element analysis (FEA) and systematic review (SR) to assess the biomechanical and clinical viability of implant‐supported crowns in MLIA scenarios ...
Leonardo Folmer Rodrigues da Silva +5 more
wiley +1 more source
Miniscrew implant applications in contemporary orthodontics
AbstractThe need for orthodontic treatment modalities that provide maximal anchorage control but with minimal patient compliance requirements has led to the development of implant‐assisted orthodontics and dentofacial orthopedics. Skeletal anchorage with miniscrew implants has no patient compliance requirements and has been widely incorporated in ...
Hong-Po Chang, Yu-Chuan Tseng
openaire +3 more sources
ABSTRACT Objective The notion that clear aligners alone can distalize upper molars without affecting anterior teeth is inaccurate. Although strategies such as Class II elastics, tooth‐movement sequencing, and attachment variations have been investigated to mitigate unwanted side effects, temporary anchorage devices have demonstrated potential for ...
Weber Jose da Silva Ursi +4 more
wiley +1 more source
INTRODUCTION The purpose of this study was to examine the overall success of miniscrews inserted in the paramedian palatal region for support of various appliances during orthodontic treatment.
Ludwig, Björn +11 more
core +1 more source