Results 31 to 40 of about 13,135 (216)

Comparison of Triply Periodic Minimal Surface Energy Absorbers Under Uniaxial Compressive Loading

open access: yesAdvanced Engineering Materials, EarlyView.
This study investigates LCD 3D printed Triply Periodic Minimal Surface (TPMS) structures as mechanical energy absorbers. By comparing various base designs and layered combinations under uniaxial compression, it identifies that a Diamond‐Gyroid sandwich structure offers superior performance.
Sergej Grednev   +2 more
wiley   +1 more source

Biomechanical investigation of long spinal fusion models using three-dimensional finite element analysis

open access: yesBMC Musculoskeletal Disorders, 2023
Background This study represents the first finite element (FE) analysis of long-instrumented spinal fusion from the thoracic vertebrae to the pelvis in the context of adult spinal deformity (ASD) with osteoporosis.
Norihiro Oku   +11 more
doaj   +1 more source

A computational and experimental assessment of the pipeline stress state under bending load and internal pressure

open access: yesИзвестия высших учебных заведений: Нефть и газ, 2021
Main pipelines are subjected to a complex of loads during operation. Monitoring of the stress state of the pipeline wall is necessary for performing strength calculations and evaluating the pipeline reliability.The article is devoted to the method of ...
A. A. Ignatik
doaj   +1 more source

Multimodal Soft Surgical Robots Enabled by Eco‐Degradable, Sterilizable Polymers and Transient Electronics

open access: yesAdvanced Functional Materials, EarlyView.
A compostable PGS soft surgical robot with interchangeable modules integrates transient Mo tactile and Si thermal sensors for dual feedback. The device preserves its function after clinical‐grade sterilization, demonstrates stable actuation and cardiac tissue grasping with real‐time in vivo pulsatile monitoring, and biodegrades post‐use with soil‐safe, 
Minseong Chae   +27 more
wiley   +1 more source

Three-dimensional finite element analysis of the biomechanical behaviour of different dental implants under immediate loading during three masticatory cycles

open access: yesHeliyon
The study aimed to evaluate the impact of varying modulus of elasticity (MOE) values of dental implants on the deformation and von Mises stress distribution in implant systems and peri-implant bone tissues under dynamic cyclic loading.
Feng Yang   +8 more
doaj   +1 more source

Dental implant primary stability in different regions of the Jawbone: CBCT-based 3D finite element analysis

open access: yesSaudi Dental Journal, 2020
Aim: This study aimed to analyze the primary stability of dental implant in maxillary and mandibular anterior and posterior regions using a finite element analysis.
Razan Alaqeely   +2 more
doaj   +1 more source

Stress Rupture Life Prediction Method for Notched Specimens Based on Minimum Average Von Mises Equivalent Stress

open access: yesMetals, 2021
Creep tests were carried out on notched plate specimens of nickel-based superalloy GH4169 with different stress concentration coefficients. It was found that the duration of the first stage of the creep curve increases with the increase of stress ...
Dawei Ji   +5 more
doaj   +1 more source

Tough, Ductile, and Strong Hard‐Soft Cementitious Composite Enabled by Multi‐Material Additive Manufacturing

open access: yesAdvanced Materials, EarlyView.
Drawing inspiration from the layered hard‐soft architecture found in sea sponges, this work establishes a new framework for architected cementitious composites (ACC) through multi‐material additive manufacturing (MMAM) process. The integration of mortar and elastomer phases into layered architectures enables synergistic toughening mechanisms, including
Aimane Najmeddine   +5 more
wiley   +1 more source

A Pressure Microsensor Made of Parylene‐C for Use as Medical Implant

open access: yesAdvanced Materials Technologies, EarlyView.
A monolithic parylene‐C pressure sensor with gold strain gauges provides 6.2 μV$\mu{\rm V}$·mmHg$\cdot{\rm mmHg}$−1$^{-1}$ sensitivity. The morphology of a sputtered thin film strain sensor is granular/columnar, which results in a high gauge factor of 7.5. Thermal bonding and parylene‐C coating create a hermetic cavity.
Ann‐Kathrin Klein   +2 more
wiley   +1 more source

Buckling‐Driven Linearity in Flexible Capacitive Pressure Sensors Based on a Three‐Dimensional Dual‐Pore Polyurethane Structure

open access: yesAdvanced Materials Technologies, EarlyView.
A flexible pressure sensor utilizing a 3D dual‐pore polyurethane structure is developed to overcome the intrinsic trade‐off between sensitivity and linearity. By inducing sequential buckling through distinct pore sizes and shapes, the device achieves highly linear and sensitive responses across a wide pressure range.
Jae Yeong Jang, Jaemin Choi, Young Jung
wiley   +1 more source

Home - About - Disclaimer - Privacy