Results 31 to 40 of about 4,784,725 (268)
Broadband single-mode microfiber coupler for OCT [PDF]
We present a bi-conical microfiber coupler (MFC) with a specifically designed transition region as an efficient tool to filter higher-order modes in multimode waveguides.
Jung, Y. +2 more
core +2 more sources
This paper presents an innovative CMOS structure for Differential Difference Transconductance Amplifiers (DDTA). While the circuit operates under extremely low voltage supply 0.5 V, the circuit’s performance is improved thanks to using the ...
Fabian Khateb +3 more
doaj +1 more source
Triple-wavelength fiber ring laser based on a hybrid gain medium actively mode-locked at 10 GHz [PDF]
A fiber ring laser based on a hybrid gain medium that produces three simultaneously mode-locked wavelength channels is presented. The lithium niobate based modulator used to actively mode-lock the laser cavity at 10 GHz is birefringence compensated to ...
Anandarajah, Prince M. +10 more
core +2 more sources
This paper presents a novel mixed-mode, low-power, 1 V analog filter that uses multiple-input multiple-output operational transconductance amplifiers (MIMO-OTAs).
Montree Kumngern +2 more
doaj +1 more source
Interacting Multiple Model Estimators for Fault Detection in a Magnetorheological Damper
This paper proposes a novel estimator for the purpose of fault detection and diagnosis. The interacting multiple model (IMM) strategy is effective for estimating the behaviour of systems with multiple operating modes.
Andrew Sanghyun Lee +3 more
doaj +1 more source
Hyperosmotic stress induces PARP1‐mediated HPF1‐dependent mono(ADP‐ribosyl)ation
Sorbitol‐induced hyperosmotic stress rapidly induces reversible mono(ADP‐ribosyl)ation (MARylation) on PARP1 without the signs of genotoxic signaling. We show that PARP1 autoMARylation is HPF1 dependent and forms hydroxylamine‐resistant O‐glycosidic linkages.
Anna Georgina Kopasz +11 more
wiley +1 more source
Partial discharge (PD) online monitoring is a common technique for high-voltage equipment diagnosis. However, due to field interference, the monitored PD signal contains a lot of noise.
Jingjie Yang +3 more
doaj +1 more source
We present robust protocols for the preparation of supported lipid bilayers (SLBs) incorporating either Salmonella smooth LPS or outer membrane vesicles (OMVs). We use a combination of quartz crystal microbalance with dissipation (QCM‐D) and fluorescence microscopy to both characterize the SLBs of various compositions and to probe their interactions ...
Hudson P. Pace +6 more
wiley +1 more source
Design and analysis strategies for robust microbiome ageing research
The gut microbiome changes with age and associates with age‐related morbidity and mortality, establishing it as a potential biomarker and intervention target for ageing. Realising this potential requires methodological rigour, yet distinguishing biological signals from methodological artefacts remains challenging across cohorts. This review provides an
Mark Olenik +5 more
wiley +1 more source
Mixed-mode oscillations with multiple time scales [PDF]
Mixed-mode oscillations (MMOs) are trajectories of a dynamical system in which there is an alternation between oscillations of distinct large and small amplitudes.
Desroches, MF +5 more
core

