Results 41 to 50 of about 765 (158)
This paper presents local condensation Heat Transfer Coefficients (HTCs) and temperature profiles of R134a and three low-GWP replacements, R1234yf, R1234ze(E), and R152a, within Brazed Plate Heat Exchangers (BPHEs).
Giovanni A. Longo, Claudio Zilio
doaj +1 more source
Flammability Comparison and Flame Retardancy Research on R32 and R1234yf
Halogenated alkanes and halogenated olefins, especially fluorine substitutes, are currently the most widely used synthetic refrigerants. With the implementation of a series of increasingly stringent environmental regulations, most optional fluorinated ...
Shi Yuqi, Yang Zhao, L
doaj
Research Progress on High-Temperature Auto-Cascade Heat Pumps
High-temperature auto-cascade heat pumps exhibit a simple and compact structure and reliable operating performance and can achieve heating at relatively high temperatures.
Cao Jiaxu Rui Shengjun Feng Tingkang Zhou Luyao He Tao
doaj
In the study, we focused on the vapor-liquid equilibrium property of the ternary system of R32+R161+R1234yf. The vapor–liquid equilibrium data was measured via a liquid-circulation apparatus at temperatures from 283.15 K to 323.15 K.
Yang Tao +3 more
doaj
Performance Test on Mixed Refrigerant in Domestic Refrigerator
J.Melvin Jones +4 more
openaire +1 more source
Experimental Investigation of R1234ze(E)/R32 Replacing R410A in Heat Pump System
Nowadays, more and more attention is being paid to the new low Global Warming Potential (GWP) refrigerant R1234ze(E). Mixing this refrigerant with R32 has been studied in recent years.
Wang Lulu, Zhang Hua, Qiu Jinyou
doaj
The two-phase flow pattern of hydrocarbon working fluids on the shell side of a helically baffled heat exchanger for liquefied natural gas determines its heat transfer performance.
Yang Guocheng +3 more
doaj
Development Status of Auto-cascade Refrigeration Technology
As a refrigeration technology with wide-temperature district, auto-cascade refrigeration has a very broad application prospect in the refrigeration and cryogenic field.
Liu Pengpeng +3 more
doaj
Composition Change Characteristics of Non-azeotropic Mixturesof Auto- cascade Refrigeration System
The condensation process of non-azeotropic mixed refrigerant is a isobaric process. Meanwhile, the concentrations of vapor and liquid continuously change.
Rui Shengjun, Zhang Hua, He Tao, Luo Hao
doaj
Efficient heat recuperation is one of the most critical factors influencing the performance of mixed-refrigerant Joule–Thomson (MR JT) cryocoolers.
Zbigniew Rogala +3 more
doaj +1 more source