Results 31 to 40 of about 149 (149)

Practical experience in commissioning ring applicators using ring applicator component type with bravos control software v1.2

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The Bravos v1.2 control software introduces a ring applicator component type (ACT) with channel length verification to address geometric characteristics and dosimetric discrepancies caused by source positioning inaccuracies. This study aims to commission the ring applicator and investigate the new ring ACT in Bravos 1.2.
Xiuxiu He   +4 more
wiley   +1 more source

Stereotactic radiosurgery for multiple small brain metastases using gamma knife versus single‐isocenter VMAT: Normal brain dose based on lesion number and size

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The study evaluates rapid linear accelerator (Linac) single isocenter stereotactic radiosurgery (SRS) with Hyperarc for large target numbers. We compared to Gamma Knife (GK), which suffers from long treatment times and investigated causes of differences. Methods Linac SRS and GK treatment plans for patients receiving 18 Gy to the gross
Abram Abdou   +4 more
wiley   +1 more source

Diagnostic image‐based treatment planning for online adaptive ultra‐hypofractionated prostate cancer radiotherapy with MR‐Linac

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose A new workflow was investigated for Elekta Unity MR‐Linac by removing the computed tomography (CT)‐simulation step and using diagnostic CT (DCT) for reference plan generation. Materials and methods Ten patients with ultra‐hypofractionated prostate cancer treated with magnetic resonance imaging (MRI)‐guided adaptive radiotherapy were ...
Yuan Xu   +5 more
wiley   +1 more source

Semi‐automated hippocampal avoidance whole‐brain radiotherapy planning

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background Hippocampal avoidance whole‐brain radiotherapy (HA‐WBRT) is designed to spare cognitive function by reducing radiation dose to the hippocampus during the treatment of brain metastases. Current manual planning methods can be time‐consuming and may vary in quality, necessitating the development of automated approaches to streamline ...
Dong Joo Rhee   +9 more
wiley   +1 more source

Evaluation of dosimetric and spatial accuracy of a virtual cone technique for radiosurgery using linac‐integrated CBCT‐based polymer gel dosimetry

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study evaluates the dosimetric and geometric precision of a virtual cone technique using CBCT‐based polymer gel dosimetry, enabling radiation delivery, and imaging readout within an identical spatial coordinate system. Methods We created a C# script for a virtual cone technique that generates a treatment plan with 10 gantry arcs ...
Tenzin Kunkyab   +6 more
wiley   +1 more source

Fast, automated optimization of virtual monoenergetic images with the dual‐energy image synthesizer for cone‐beam CT

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background Dual‐energy cone‐beam CT (DE‐CBCT) has become subject of recent interest due to the ability to produce virtual monoenergetic images (VMIs) with improved soft‐tissue contrast and reduced nonuniformity artifacts. However, efficient production and optimization of VMIs remains an under‐explored part of DE‐CBCT's application.
Andrew Keeler   +4 more
wiley   +1 more source

Surface dose analysis and dosimetric comparison of Halcyon versus Truebeam in breast cancer radiotherapy: An OSL dosimetry study

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Breast cancer is a neoplastic disease with high prevalence among women. Radiotherapy is one of the principal treatment modalities for this disease, but it poses significant challenges. This study aimed to compare and evaluate the technical and dosimetric performance of conventional C‐arm linac systems and a new design, Halcyon, in the ...
Mustafa Çağlar   +8 more
wiley   +1 more source

Comprehensive clinical evaluation of novel 4DCT‐based lung function imaging methods

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Methods have been developed that apply image processing to 4DCTs to generate 4DCT‐ventilation/perfusion lung imaging. Traditional methods for 4DCT‐ventilation rely on Hounsfield‐Unit (HU) density‐change methods and suffer from poor numerical robustness while not providing 4DCT‐perfusion data.
Ehsan Golkar   +6 more
wiley   +1 more source

Novel CT radiomics models for the postoperative prediction of early recurrence of resectable pancreatic adenocarcinoma: A single‐center retrospective study in China

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To assess the predictive capability of CT radiomics features for early recurrence (ER) of pancreatic ductal adenocarcinoma (PDAC). Methods Postoperative PDAC patients were retrospectively selected, all of whom had undergone preoperative CT imaging and surgery. Both patients with resectable or borderline‐resectable pancreatic cancer met
Xinze Du   +7 more
wiley   +1 more source

Implementation of needle‐tracking technology for real‐time transrectal ultrasound‐guided interstitial gynecological HDR brachytherapy: A feasibility study

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To investigate the feasibility of adapting a commercial prostate biopsy system for transrectal ultrasound (TRUS)‐guided hybrid gynecological (GYN) high‐dose‐rate (HDR) brachytherapy (BT). Leveraging 3D‐TRUS and MR image fusion, the prototype system aims to improve real‐time needle placement accuracy.
Lindsey H. Bloom   +8 more
wiley   +1 more source

Home - About - Disclaimer - Privacy