Results 171 to 180 of about 1,772,053 (358)

Effects of cardiac motion on dose distribution during stereotactic arrhythmia radioablation treatment: A simulation and phantom study

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Cardiac motion may degrade dose distribution during stereotactic arrhythmia radioablation using the CyberKnife system, a robotic radiosurgery system. This study evaluated the dose distribution changes using a self‐made cardiac dynamic platform that mimics cardiac motion. Methods The cardiac dynamic platform was operated with amplitudes
Takayuki Miyachi   +6 more
wiley   +1 more source

Multi‐institutional study on image quality for a novel CBCT solution on O‐ring linac

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Introduction This work presents a multi‐institutional study on image quality provided by a novel cone beam computed tomography (CBCT). The main goal is to investigate the consistency of imaging performance across multiple institutions.
Luis Agulles‐Pedrós   +11 more
wiley   +1 more source

The neutron spectral moments method in the time-of-flight domain [PDF]

open access: yesarXiv
An analysis methodology is developed for the time-of-flight (TOF) signals recorded by two or more collinear neutron detectors located at different distances from a pulsed neutron source. It is based on taking central moments of the TOF signals and relating these to a set of co-moments of the distribution of production times and velocities of neutrons ...
arxiv  

JACMP – Founding and 2000–2004

open access: yes
Journal of Applied Clinical Medical Physics, EarlyView.
Michael Mills
wiley   +1 more source

From 2D to 3D gamma passing rate tolerance and action limits for patient‐specific quality assurance in volumetric‐modulated arc therapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background Volumetric modulated arc therapy (VMAT) requires an accurate patient‐specific quality assurance (PSQA) program. In clinical practice, this is usually performed using the γ‐index and the two‐dimensional gamma passing rate (2D %GP). A three‐dimensional (3D) index incorporating the patient anatomy could be more useful for the 3D dose ...
Christos Zarros   +6 more
wiley   +1 more source

JACMP 2005–2009

open access: yes
Journal of Applied Clinical Medical Physics, EarlyView.
Timothy D. Solberg
wiley   +1 more source

Measurement of CT radiation beam width with a pencil ionization chamber and radiopaque mask

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study compares fan beam CT scanner radiation beam widths measured with a pencil ionization chamber‐radiopaque mask technique with commonly used film and computed radiography (CR) measurements. Methods For a given fan beam CT scanner x‐ray beam, the ionization chamber‐mask technique determines the radiation beam width by exposing a
Rani Al‐Senan   +2 more
wiley   +1 more source

JACMP 2025–2029 and beyond

open access: yes
Journal of Applied Clinical Medical Physics, EarlyView.
Michael Mills
wiley   +1 more source

Evaluation of daily residual pancreatic tumor motion for deep‐inspiration breath‐hold radiotherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Breath‐hold techniques are widely used in radiation therapy to minimize respiratory‐induced tumor or organ‐at‐risk motion. However, residual motion persists, necessitating a reliable daily evaluation method. Methods At our institution, fiducial markers serve as surrogates for target localization in pancreatic cancer treatment.
Weihua Mao   +4 more
wiley   +1 more source

JACMP 2010–2014

open access: yes
Journal of Applied Clinical Medical Physics, EarlyView.
George Starkschall
wiley   +1 more source

Home - About - Disclaimer - Privacy