Results 261 to 270 of about 1,772,053 (358)

Design and validation of a novel dosimetry phantom for motion management audits

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background We present a novel phantom design for conducting end‐to‐end dosimetry audits for respiratory motion management of two anatomical treatment sites. The design enables radiochromic film measurements of the dose administered to the target throughout the respiratory cycle (motion‐included) and the dose delivered to the time‐averaged ...
Alex Burton   +5 more
wiley   +1 more source

A Python package for fast GPU‐based proton pencil beam dose calculation

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Open‐source GPU‐based Monte Carlo (MC) proton dose calculation algorithms provide high speed and unparalleled accuracy but can be complex to integrate with new applications and remain slower than GPU‐based pencil beam (PB) methods, which sacrifice some physical accuracy for sub‐second plan calculation.
Mahasweta Bhattacharya   +4 more
wiley   +1 more source

Giant Rashba splitting in PtTe/PtTe<sub>2</sub> heterostructure. [PDF]

open access: yesNat Commun
Feng R   +13 more
europepmc   +1 more source

Log file‐based quality assurance method for respiratory gating system

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background As medical linear accelerator technology advances, enabling higher dose rate deliveries, hypofractionation regimens has increased. This necessitates respiratory gating systems that synchronize radiation delivery with tumor position, requiring simple rigorous quality assurance (QA) to ensure treatment accuracy and patient safety ...
Wonjoong Cheon   +7 more
wiley   +1 more source

Connection between f-electron correlations and magnetic excitations in UTe2. [PDF]

open access: yesNPJ Quantum Mater
Halloran T   +10 more
europepmc   +1 more source

Machine stability and dosimetry for ultra‐high dose rate FLASH radiotherapy human clinical protocol

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The FLASH effect, induced by ultra‐high dose rate (UHDR) irradiations, offers the potential to spare normal tissue while effectively treating tumors. It is important to achieve precise and accurate dose delivery and to establish reliable detector systems, particularly for clinical trials needed to help the clinical transfer of FLASH‐
Patrik Gonçalves Jorge   +9 more
wiley   +1 more source

Home - About - Disclaimer - Privacy