Results 171 to 180 of about 54,828 (282)

All‐in‐One Analog AI Hardware: On‐Chip Training and Inference with Conductive‐Metal‐Oxide/HfOx ReRAM Devices

open access: yesAdvanced Functional Materials, EarlyView.
An all‐in‐one analog AI accelerator is presented, enabling on‐chip training, weight retention, and long‐term inference acceleration. It leverages a BEOL‐integrated CMO/HfOx ReRAM array with low‐voltage operation (<1.5 V), multi‐bit capability over 32 states, low programming noise (10 nS), and near‐ideal weight transfer.
Donato Francesco Falcone   +11 more
wiley   +1 more source

Printed Integrated Logic Circuits Based on Chitosan‐Gated Organic Transistors for Future Edible Systems

open access: yesAdvanced Functional Materials, EarlyView.
Edible electronics needs integrated logic circuits for computation and control. This work presents a potentially edible printed chitosan‐gated transistor with a design optimized for integration in circuits. Its implementation in integrated logic gates and circuits operating at low voltage (0.7 V) is demonstrated, as well as the compatibility with an ...
Giulia Coco   +8 more
wiley   +1 more source

Laser‐Induced Graphene from Waste Almond Shells

open access: yesAdvanced Functional Materials, EarlyView.
Almond shells, an abundant agricultural by‐product, are repurposed to create a fully bioderived almond shell/chitosan composite (ASC) degradable in soil. ASC is converted into laser‐induced graphene (LIG) by laser scribing and proposed as a substrate for transient electronics.
Yulia Steksova   +9 more
wiley   +1 more source

Magnetic Control of Chiral Hybridized Phonon Magnetic Moments in Ferrimagnets Fe2‐xZnxMo3O8

open access: yesAdvanced Functional Materials, EarlyView.
Helicity‐resolved magneto‐Raman spectroscopy reveals magnetic control of chiral phonon magnetic moments in polar ferrimagnet (ZnxFe2−xMo3O₈). Large spontaneous zero‐field phonon splittings, selective phonon–magnon coupling, and asymmetric Zeeman responses demonstrate that phonon chirality is governed by magnon‐phonon coupling and magnetization.
Youngsu Choi   +8 more
wiley   +1 more source

Hot‐Film and Calorimetric Methods With Transient Heating for Measurement of High Biofluid Flow Rate

open access: yesAdvanced Functional Materials, EarlyView.
Accurate measurement of biofluid flow rate is vital for clinical diagnostics. We propose a transient heating strategy using short thermal pulses and peak temperature tracking to enhance the flow sensitivity of the hot‐Film and calorimetric methods. Simulations show how optimal heating time maximizes sensitivity across flow rates.
Yuanting Wei   +8 more
wiley   +1 more source

Home - About - Disclaimer - Privacy