Results 231 to 240 of about 5,795,564 (318)
Effects of vasectomy on breeding-related movement and activity in free-ranging white-tailed deer. [PDF]
DeNicola V+4 more
europepmc +1 more source
Abstract Purpose This study evaluates the dosimetric and geometric precision of a virtual cone technique using CBCT‐based polymer gel dosimetry, enabling radiation delivery, and imaging readout within an identical spatial coordinate system. Methods We created a C# script for a virtual cone technique that generates a treatment plan with 10 gantry arcs ...
Tenzin Kunkyab+6 more
wiley +1 more source
Stem introducer designs and surgical technique play a significant role in achieving the optimal implant-cement interface. [PDF]
van Duren BH+6 more
europepmc +1 more source
Abstract Purpose This study aims to evaluate the accuracy of the frameless linear accelerator‐based stereotactic radiosurgery (FSRS) system incorporating cone‐beam CT (CBCT), six degrees of freedom (6‐DoF) couch, room laser, and surface image‐guided (SG) systems.
Hao‐Wen Cheng+4 more
wiley +1 more source
Comparative Analysis of Machine Learning Approaches for Fetal Movement Detection with Linear Acceleration and Angular Rate Signals. [PDF]
Spicher L, Bell C, Sienko KH, Huan X.
europepmc +1 more source
Design and validation of a novel dosimetry phantom for motion management audits
Abstract Background We present a novel phantom design for conducting end‐to‐end dosimetry audits for respiratory motion management of two anatomical treatment sites. The design enables radiochromic film measurements of the dose administered to the target throughout the respiratory cycle (motion‐included) and the dose delivered to the time‐averaged ...
Alex Burton+5 more
wiley +1 more source
Musculoskeletal rehabilitation in controlled trials: Is it correct to compare different types of exercise? [PDF]
Pontes-Silva A.
europepmc +1 more source
A Python package for fast GPU‐based proton pencil beam dose calculation
Abstract Purpose Open‐source GPU‐based Monte Carlo (MC) proton dose calculation algorithms provide high speed and unparalleled accuracy but can be complex to integrate with new applications and remain slower than GPU‐based pencil beam (PB) methods, which sacrifice some physical accuracy for sub‐second plan calculation.
Mahasweta Bhattacharya+4 more
wiley +1 more source
Amplitude fluctuations of cerebrovascular oscillations and CSF movement desynchronize during NREM3 sleep. [PDF]
Nair VV+6 more
europepmc +1 more source
Nilesh A Nadkarni, Shrikant S Deshmukh
openaire +3 more sources