Results 321 to 330 of about 6,047,402 (368)

Profile of the PLAY spaces & environments for children's physical activity, sedentary behaviour and sleep (PLAYCE) cohort study, Western Australia. [PDF]

open access: yesJ Act Sedentary Sleep Behav
Christian H   +8 more
europepmc   +1 more source

Log file‐based quality assurance method for respiratory gating system

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background As medical linear accelerator technology advances, enabling higher dose rate deliveries, hypofractionation regimens has increased. This necessitates respiratory gating systems that synchronize radiation delivery with tumor position, requiring simple rigorous quality assurance (QA) to ensure treatment accuracy and patient safety ...
Wonjoong Cheon   +7 more
wiley   +1 more source

Pathogen-induced alterations in fine-scale movement behaviour predict impaired reproductive success. [PDF]

open access: yesProc Biol Sci
Grabow M   +11 more
europepmc   +1 more source

Machine stability and dosimetry for ultra‐high dose rate FLASH radiotherapy human clinical protocol

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The FLASH effect, induced by ultra‐high dose rate (UHDR) irradiations, offers the potential to spare normal tissue while effectively treating tumors. It is important to achieve precise and accurate dose delivery and to establish reliable detector systems, particularly for clinical trials needed to help the clinical transfer of FLASH‐
Patrik Gonçalves Jorge   +9 more
wiley   +1 more source

Accounting for TLD response to CBCT protocols in external beam radiotherapy dose monitoring

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose LiF thermoluminescent dosimeters (TLDs) are commonly used in radiation therapy to verify the delivered dose. Examples include dose verification for complicated treatment setups or cardiovascular implantable electronic devices (CIEDs). TLDs may be present for both the pre‐treatment imaging kilovoltage (kV) beam and the megavoltage (MV ...
Andrew J. White   +5 more
wiley   +1 more source

Reliability of Brain Activity During a Supine Bilateral Leg Press and Association With Concurrent 3D Knee Joint Biomechanics. [PDF]

open access: yesEur J Neurosci
Kim H   +10 more
europepmc   +1 more source

DICOM attribute manipulation tool: Easily change frame of reference, series instance, and SOP instance UID

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose In radiation oncology, the integration and registration of multiple imaging modalities is a crucial aspect of the diagnosis and treatment planning process. These images are often inherently registered, a useful feature in most cases, but possibly a hindrance when registration modifications are required.
Brian M. Anderson, Casey Bojechko
wiley   +1 more source

An investigation into the feasibility and efficacy of stereotactic radiosurgery for 1–3 cm single brain lesions on the ring‐mounted Halcyon LINAC

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose An evaluation of the accuracy, safety, and efficiency of the Halcyon ring delivery system (RDS) for stereotactic radiosurgery (SRS) treatment to relatively small (1–3 cm) brain lesions. Methods After completing the extensive in‐house quality assurance checks including Winston–Lutz test and independent dose verification via MD Anderson ...
Kate Hazelwood   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy