Biomedical engineering and physics express
Purpose. To investigate the effect of the position and orientation of the detector and its influence on the determination of output factors (OF) for small fields for a linear accelerator (MR-linac) integrated with 1.5 T magnetic resonance following the ...
J. A. Rojas-López +4 more
semanticscholar +1 more source
Purpose. To investigate the effect of the position and orientation of the detector and its influence on the determination of output factors (OF) for small fields for a linear accelerator (MR-linac) integrated with 1.5 T magnetic resonance following the ...
J. A. Rojas-López +4 more
semanticscholar +1 more source
Physics in Medicine and Biology
Objective. The Elekta unity MR-linac delivers step-and-shoot intensity modulated radiotherapy plans using a multileaf collimator (MLC) based on the Agility MLC used on conventional Elekta linacs.
R.G.J. Kierkels +7 more
semanticscholar +1 more source
Objective. The Elekta unity MR-linac delivers step-and-shoot intensity modulated radiotherapy plans using a multileaf collimator (MLC) based on the Agility MLC used on conventional Elekta linacs.
R.G.J. Kierkels +7 more
semanticscholar +1 more source
Current Status of MR-Linac System.
Igaku butsuri : Nihon Igaku Butsuri Gakkai kikanshi = Japanese journal of medical physics : an official journal of Japan Society of Medical Physics, 2018Current status of MR-Linac System was reported. First, we introduced the history of development about MR-Linac System. We discussed the advantage of MR-Linac for radiotherapy. Next, we explained the electron return effect caused by magnetic field, resulting in different dose distribution, compared to dose distribution with no magnetic field.
openaire +1 more source
Dose accuracy for the MR-linac
The introduction of the MR-linac marked a major milestone in the field of radiotherapy. The MR-linac uses a linear accelerator (Linac) combined with an MRI scanner. MRI allows excellent soft-tissue visualization, and the integrated system enables 3D imaging immediately before and during treatment.openaire +1 more source
“Unity” (MR-LINAC) workflow and patient cases
Journal of Medical Imaging and Radiation Sciences, 2022Dongjoon Yang +4 more
openaire +1 more source
MRgRT Quality Assurance for a Low-Field MR-Linac
Seminars in Radiation OncologyThe introduction of MR-guided treatment machines into the radiation oncology clinic has provided unique challenges for the radiotherapy QA program. These MR-linac systems require that existing QA procedures be adapted to verify linac performance within the magnetic field environment and that new procedures be added to ensure acceptable image quality ...
openaire +2 more sources