Results 231 to 240 of about 1,090,723 (249)

Clinical Use of S53P4 Bioactive Glass in the Treatment of Bone Defects and Infected Bone: A Systematic Review of the Quality of Clinical Outcomes and A Grade Assessment

open access: yesAdvanced Healthcare Materials, EarlyView.
Bioactive glass (BAG) S53P4 is a synthetic bone substitute. Clinically it has been used in the treatment of benign bone tumor surgery, in spine surgery, in trauma surgery, in frontal sinus surgery, in diabetic foot osteomyelitis surgery, in mastoid surgery, in oral and maxillofacial surgery in more than 4000 patients, with excellent clinical long‐term ...
Sebastian CE Lindfors   +2 more
wiley   +1 more source

Where Is the Filler? Magnetic Resonance Imaging Reveals Hidden Hyaluronic Acid in a Delayed Chin Complication. [PDF]

open access: yesPlast Reconstr Surg Glob Open
Mariluis CA   +3 more
europepmc   +1 more source

Preliminary Study of a Ninj1‐Loaded Bimodal Ultrasound/NIR Fluorescence Targeted Molecular Probe for Diagnosing Early‐Stage Inflammation in Coronary Microvascular Dysfunction

open access: yesAdvanced Healthcare Materials, EarlyView.
Coronary microvascular dysfunction (CMD) targeting remains a challenge for precise diagnosis. This work presents a dual‐modal nanoprobe (T‐IR780‐NBs) that combines ultrasound contrast with near‐infrared fluorescence. This technology utilizes proteomics‐derived antibodies that specifically localize to inflamed and injured cardiac tissue, enabling ...
Xiaohui Xu   +6 more
wiley   +1 more source

Enhancing Magnetic Hyperthermia at the Cell Membrane by Anchoring 92R‐Functionalized Magnetic Nanoparticles to Low‐Endocytic CCR9 Surface Receptors

open access: yesAdvanced Healthcare Materials, EarlyView.
We present a strategy to enhance magnetic hyperthermia therapy by modulating nanoparticle–cell interactions. Antibody‐functionalized magnetic nanoparticles targeting the low‐internalizing CCR9 receptor enable spatially controlled membrane anchoring, reducing aggregation and maximizing heat generation under alternating magnetic fields.
David Egea‐Benavente   +5 more
wiley   +1 more source

Smart Catheters for Diagnosis, Monitoring, and Therapy

open access: yesAdvanced Healthcare Materials, EarlyView.
This study presents a comprehensive review of smart catheters, an emerging class of medical devices that integrate embedded sensors, robotics, and communication systems, offering increased functionality and complexity to enable real‐time health monitoring, diagnostics, and treatment. Abstract This review explores smart catheters as an emerging class of
Azra Yaprak Tarman   +12 more
wiley   +1 more source

Assessing cervical intervertebral disc height on MRI and X-ray versus CT; a single center retrospective cohort study. [PDF]

open access: yesBrain Spine
van Santbrink E   +6 more
europepmc   +1 more source

Boron‐Doped Nano‐Crystalline Coated Carbon Fibers for Phasic Dopamine Sensing

open access: yesAdvanced Healthcare Materials, EarlyView.
This uniform coating presents a mix of graphitic and diamond‐like carbon to create a mechanically and electrically robust alternative for the electrochemical detection of dopamine. The electrodes in this work possess the equivalent sensitivity to the state‐of‐the‐art FSCV dopamine detecting electrodes, whilst demonstrating an ability to withstand ...
Simon J. Higham   +19 more
wiley   +1 more source

Home - About - Disclaimer - Privacy