Results 171 to 180 of about 54,811 (238)
Long Term Visual Outcomes Following Implantation of a New Hydrophobic IOL in a Real-World Clinical Setting. [PDF]
Agarwal S, Chang LY, Thornell E.
europepmc +1 more source
Quantitative CT reconstruction kernel harmonization for multi-site lung cancer screening. [PDF]
Jordan DW, Misseldine RE.
europepmc +1 more source
Correlation between exposure (mAs) and image quality for a rapid cone-beam CT on a ring gantry linear accelerator. [PDF]
Zhao H +9 more
europepmc +1 more source
Holographic effect through full parallax multi-viewpoint augmented reality with extended depth of field. [PDF]
Yoon J, Yoon KH, Choi W, Kim SK.
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
IEEE Transactions on Electron Devices, 2001
In this paper, a unified model, based on a thorough analysis of experimental data, is developed for the overall modulation transfer function (MTF) estimation for CMOS image sensors. The model covers the physical diffusion effect together with the influence of the pixel active area geometrical shape.
I. Shcherback, O. Yadid-Pecht
openaire +1 more source
In this paper, a unified model, based on a thorough analysis of experimental data, is developed for the overall modulation transfer function (MTF) estimation for CMOS image sensors. The model covers the physical diffusion effect together with the influence of the pixel active area geometrical shape.
I. Shcherback, O. Yadid-Pecht
openaire +1 more source
Applied Optics, 1973
The effect of shot noise on the MTF of a lens when measured by means of an edge scan is treated both analytically and experimentally. It is shown that the variance in the MTF, introduced by the shot noise, establishes an upper bound on the magnitude of any systematic error introduced into the MTF measurement by the noise.
openaire +2 more sources
The effect of shot noise on the MTF of a lens when measured by means of an edge scan is treated both analytically and experimentally. It is shown that the variance in the MTF, introduced by the shot noise, establishes an upper bound on the magnitude of any systematic error introduced into the MTF measurement by the noise.
openaire +2 more sources
MTF Optimization in Lens Design
International Lens Design, 1990Optimization programs generally use a merit function which is related to mean square spot size or wave aberration. Direct MTF optimization has been tried, but with limited success. One problem, which makes it almost unusable in the early stages of the design, is the fact that MTF values are bounded between 0.0 and 1.0 and oscillate significantly as a ...
Matthew P. Rimmer +2 more
openaire +1 more source
SPIE Proceedings, 1993
A method for measuring imaging system MTF is presented that is compatible with modeling predictions as implemented in the Army's FLIR90/92 static performance model. The method uses commonly available commercial test equipment and personal computers and is effective for measuring scanning and staring array imaging systems in any imaging orientation ...
Benjamin S. White, Michael J. Marquis
openaire +1 more source
A method for measuring imaging system MTF is presented that is compatible with modeling predictions as implemented in the Army's FLIR90/92 static performance model. The method uses commonly available commercial test equipment and personal computers and is effective for measuring scanning and staring array imaging systems in any imaging orientation ...
Benjamin S. White, Michael J. Marquis
openaire +1 more source

