Results 101 to 110 of about 1,817,721 (192)
Auto-detection of cervical collagen and elastin in Mueller matrix polarimetry microscopic images using K-NN and semantic segmentation classification. [PDF]
Roa C +4 more
europepmc +1 more source
International audienceExperimental results are presented related to the dynamic behaviour of Polymer Stabilized Ferro-electric Liquid Crystal (PSFLC) samples under external applied electric field, using Snap-shot Mueller Matrix Polarimetry (SMMP) and ...
Silva, Vinicius +11 more
core +1 more source
Mueller matrix polarimetry with 3D integral imaging
In this paper, we introduce the Mueller matrix imaging concepts for 3D Integral Imaging Polarimetry. The Mueller matrix of a complex scene is measured and estimated with 3D integral imaging.
Carnicer González, Arturo +2 more
core
As an emerging powerful tool to provide structural information of tissue specimens label-freely, Mueller matrix (MM) polarimetry has garnered extensive attention in biomedical studies and pathological diagnosis.
Kaisha Deng +9 more
doaj +1 more source
In Mueller matrix polarimetry, the accuracy of polarimeter calibration directly determines the reliability of measurement results. As a general calibration method, the eigenvalue calibration method (ECM) is widely adopted since it does not require exact ...
Zhiyong Yang +4 more
doaj +1 more source
IntroductionLabel-free quantitative polarimetric imaging provides access to physically interpretable tissue properties that are not available from conventional intensity-based microscopy, offering new opportunities for computational digital pathology and
Yuxuan Mao +4 more
doaj +1 more source
Non-Invasive Glucose Sensing on Fingertip Using a Mueller Matrix Polarimetry With Machine Learning
This study achieved significant predictive results using Mueller Matrix Polarimetry combined with the XGBoost algorithm for non-invasive glucose sensing of biological tissues on human fingertips.
Chih-Yi Liu, Yu-Lung Lo, Wei-Chun Hung
doaj +1 more source
This work presents a complete Mueller matrix imaging polarimeter that uses three liquid-crystal retarders and a pixelated polarization camera. The polarimeter is characterized and optimized with a standard correction procedure here adapted to be ...
Nabadda Esther +5 more
doaj +1 more source
Mueller Matrix Imaging and Spectroscopy
This thesis presents experimental work on the following topics in Mueller matrix polarimetry; instrument design and implementation, and selected applications of liquid crystal based Mueller matrix polarimeters (MMP) and spectroscopic Mueller matrix ...
Aas, Lars Martin Sandvik
core +1 more source
To enhance the clinical utility of mass spectrometry (MS), lengthy dwell times on less informative regions of patient specimens (e.g., adipose tissue in breast) must be minimized. Additionally, a promising variant of MS known as picosecond infrared laser
Michael D. Singh +5 more
doaj +1 more source

