Results 101 to 110 of about 1,736,933 (175)
Review of polarization-based technology for biomedical applications
Polarimetry is a powerful optical tool in the biomedical field, providing more comprehensive information on the sub-wavelength micro-physical structure of a sample than traditional light intensity measurement techniques.
Caizhong Guan, Nan Zeng, Honghui He
doaj +1 more source
Retinal Imaging: Acquisition, Processing, and Application of Mueller Matrix Confocal Scanning Laser Polarimetry [PDF]
The focus of this thesis is the improvement of acquisition and processing of Mueller matrix polarimetry using a confocal scanning laser ophthalmoscope (CSLO) and the application of Mueller matrix polarimetry to image the retina.
Cookson, Christopher James
core
A new Mueller ellipsometry method was proposed for characterising the optical properties of thin films with rough surfaces. The validity of the proposed study is demonstrated by comparing the experimental results of the refractive index and thickness of ...
Phan Quoc-Hung, Lo Yu-Lung
doaj +1 more source
Bayesian inference approach for Full Poincaré Mueller polarimetry
© 2023 Elsevier Ltd.Full Poincare Mueller Polarimetry is a new technique for characterizing samples by means of their Mueller matrix. The method is based on the use of a full Poincare beam as a generator of polarization states.
Juan Carlos Suárez-Bermejo +16 more
core +1 more source
Probing intrinsic anisotropies of fluorescence: Mueller matrix approach
We demonstrate that information on "intrinsic" anisotropies of fluorescence originating from preferential orientation/organization of fluorophore molecules can be probed using a Mueller matrix of fluorescence.
Kumar, Uday +4 more
core +1 more source
Probing volume phase transition behavior of super-diluted polymer solutions both micro- and macroscopically still persist as an outstanding challenge. In this regard, we have explored 4x4 spectral Mueller matrix measurement and its inverse analysis for ...
Chandel, Shubham +3 more
core +2 more sources
Mueller matrix polarimetry with 3D integral imaging
In this paper, we introduce the Mueller matrix imaging concepts for 3D Integral Imaging Polarimetry. The Mueller matrix of a complex scene is measured and estimated with 3D integral imaging.
Carnicer González, Arturo +2 more
core
This work presents a complete Mueller matrix imaging polarimeter that uses three liquid-crystal retarders and a pixelated polarization camera. The polarimeter is characterized and optimized with a standard correction procedure here adapted to be ...
Nabadda Esther +5 more
doaj +1 more source
To enhance the clinical utility of mass spectrometry (MS), lengthy dwell times on less informative regions of patient specimens (e.g., adipose tissue in breast) must be minimized. Additionally, a promising variant of MS known as picosecond infrared laser
Michael D. Singh +5 more
doaj +1 more source
Polarization cameras including 4-directional micro-polarizer array sensors are a very novel technology that have shown potential for fast and in-situ polarimetric measurement, which results in very appealing in applications, such as biomedical, astronomy,
Ivan MONTES-GONZALEZ +4 more
doaj +1 more source