Results 11 to 20 of about 259,965 (163)
In this paper, we review different designs of distributed Raman amplifiers which have been proposed to minimize the signal power profile asymmetry in mid-link optical phase conjugation systems.
Mingming Tan +8 more
doaj +1 more source
Improving transmission lines (TL) steady-state stability limit can be achieved by Static Synchronous Series Compensators (SSSC) that work as a converter-based compensator.
Ahmed E. Elgebaly +3 more
doaj +1 more source
A new theory for torsional stiffness of multi-span bundle overhead transmission lines [PDF]
A new theory for the torsional stiffness of multi-span bundle overhead power transmission lines is presented. The torsional mechanism is clarified. A simplified torsional stiffness formula is obtained which allows for the complex bundle stiffness to be directly calculated from the basic parameters.
Wang, Jianwei, Lilien, Jean-Louis
openaire +1 more source
Investigation Into the Galloping Characteristics of Multispan Iced Covered Conductors
A full multispan two-degree-of-freedom (2-DOF) iced covered transmission line model is presented. Taking multispan conductors as the research object, based on the Hamiltonian principle, a nonlinear galloping model of multispan conductors considering the ...
Jia-Yan Zheng +2 more
doaj +1 more source
A compact incoherent broadband cavity-enhanced absorption spectrometer for trace detection of nitrogen oxides, iodine oxide and glyoxal at levels below parts per billion for field applications [PDF]
We present a compact, affordable and robust instrument based on incoherent broadband cavity-enhanced absorption spectroscopy (IBBCEAS) for simultaneous detection of NOx, IO, CHOCHO and O3 in the 400–475 nm wavelength region.
A. Barbero +5 more
doaj +1 more source
In the test of cross span distance of transmission line, the estimation of cross span distance is not accurate, which leads to the increase of subsequent test error.
Qiaoyun Xu +4 more
semanticscholar +1 more source
Calculation Method for dynamic Stiffness of multi-span overhead transmission lines
The dynamic motion of a span is coupled to the other spans in transmission lines. From the continuity conditions, force equilibrium conditions, and dynamical equations of every span conductor and insulator string, a close-form expression for the dynamic ...
Lv Zhongbin +6 more
semanticscholar +1 more source
The wind-induced fatigue is the main factor leading to reduction of the bearing capacity of long-span transmission towers. In order to reduce the harm of wind vibration, this paper takes the 500 kV Jiamusi region ISLSTT (in service long span transmission
Jinghua Liu +4 more
doaj +1 more source
Towards a System Theoretic Approach to Wireless Network Capacity in Finite Time and Space [PDF]
In asymptotic regimes, both in time and space (network size), the derivation of network capacity results is grossly simplified by brushing aside queueing behavior in non-Jackson networks.
Ciucu, Florin +4 more
core +2 more sources
Predicting wildfire ignition induced by dynamic conductor swaying under strong winds
During high wind events with dry weather conditions, electric power systems can be the cause of catastrophic wildfires. In particular, conductor-vegetation contact has been recognized as the major ignition cause of utility-related wildfires.
Xinyue Wang, Paolo Bocchini
doaj +1 more source

