Results 211 to 220 of about 2,172 (237)
Abstract Discrete nebulization using aerosol deposition is examined as a procedure for sample introduction in electrothermal vaporization for ICP-AES. Small volumes of solution (
Henryk Matusiewicz, Ramón M. Barnes
openalex +3 more sources
AbstractA comparison of slurry sampling (SS)‐ETV‐ICP‐MS and slurry nebulization (SN)‐ICP‐MS for direct determination of trace impurities in titanium dioxide powder is made. The particle size effect, matrix effect and analytical characteristics of SSETV‐ICP‐MS and SN‐ICP‐MS are compared. The results have shown that SSETV‐ICP‐MS has a lower particle size
Guoqiang Xiang +3 more
openalex +4 more sources
Abstract A new method for quantification of spectral interferences based on analyte isotope ratio measurements in the presence of various concentrations of a specific matrix is presented. Within the method, a tolerance level is used, defined as the matrix concentration at which the ratio between analyte isotopes with and without interferences is ...
Erik Björn +3 more
openalex +3 more sources
Jaap W. Elgersma +2 more
openalex +3 more sources
Preparation of zirconia thin films by metalorganic chemical vapor deposition using ultrasonic nebulization [PDF]
Zirconia (ZrO2) thin films were prepared by metalorganic chemical vapor deposition (MOCVD) using ultrasonic nebulization with new source materials, Zr(OBu)4, Zr(OBu)3(acac), Zr(OBu)2(acac)2, and Zr(OBu) (acac)3. This process is a simple and economic method to prepare oxide thin films.
Dong Young Kim +2 more
openaire +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Journal of Analytical Atomic Spectrometry, 2022
The vapor generation process of Hg2+ and MeHg+ to form volatile Hg0 was found in aqueous microdroplets produced by pneumatic nebulization without any added redox agent, electricity or radiation.
Qian He +4 more
openaire +1 more source
The vapor generation process of Hg2+ and MeHg+ to form volatile Hg0 was found in aqueous microdroplets produced by pneumatic nebulization without any added redox agent, electricity or radiation.
Qian He +4 more
openaire +1 more source
Vapor-generation assisted nebulization for nonmetal determination
Spectrochimica Acta Part B: Atomic Spectroscopy, 1995Abstract A new on-line vapor-generation nebulization (VGN) method is explored for non-metal detection by microwave plasma torch-mass spectrometry (MPT-MS). In the new method, a three-channel “Y” is used to introduce the sample and reactant solutions simultaneously into a nebulizer.
Qinhan Jin +3 more
openaire +2 more sources
Journal of Materials Research, 2021
In this work, we have coated 0, 1, 3, and 5 wt% of Erbium (Er)-doped tin oxide (SnO2) films on glass using a simple nebulizer spray pyrolysis method to make an ammonia vapor sensor with remarkable sensitivity. X-ray diffraction, Atomic force microscopy, Ultraviolet–visible spectroscopy and photoluminescence methods were employed to inspect the thin ...
Mohd. Shkir +8 more
openaire +2 more sources
In this work, we have coated 0, 1, 3, and 5 wt% of Erbium (Er)-doped tin oxide (SnO2) films on glass using a simple nebulizer spray pyrolysis method to make an ammonia vapor sensor with remarkable sensitivity. X-ray diffraction, Atomic force microscopy, Ultraviolet–visible spectroscopy and photoluminescence methods were employed to inspect the thin ...
Mohd. Shkir +8 more
openaire +2 more sources
Journal of Analytical Atomic Spectrometry, 2022
A sensitive procedure was developed for trace Cr determination by ICP MS with a DDTC enhanced nebulized film dielectric barrier discharge (NFDBD) vapor generation sampling system.
Qian He +4 more
openaire +1 more source
A sensitive procedure was developed for trace Cr determination by ICP MS with a DDTC enhanced nebulized film dielectric barrier discharge (NFDBD) vapor generation sampling system.
Qian He +4 more
openaire +1 more source