Multi-Channel Neural Interface for Neural Recording and Neuromodulation. [PDF]
Kim E +9 more
europepmc +1 more source
Understanding the Effects of Conductive Polymer Electrode Coating on Recorded Neural Signals
Conductive polymer coatings are widely explored to improve the quality of signals recorded with chronically implanted neural electrodes, offering enhanced biocompatibility along with reduced electrode impedance. Combining computational modelling and data from PEDOT:PTS coated and PtIr electrodes in rats, we show that improvements in signal quality with
Karthik Sridhar +4 more
wiley +1 more source
Intraoperative Impedance Gradient as a Physiological Indicator of Electrode-Neural Interface in Pediatric Cochlear Implantation. [PDF]
Sinha R, Nandan M, Sharma AK, Singh RK.
europepmc +1 more source
Optimized design of a hyperflexible sieve electrode to enhance neurovascular regeneration for a peripheral neural interface. [PDF]
Veith A +6 more
europepmc +1 more source
Smart Catheters for Diagnosis, Monitoring, and Therapy
This study presents a comprehensive review of smart catheters, an emerging class of medical devices that integrate embedded sensors, robotics, and communication systems, offering increased functionality and complexity to enable real‐time health monitoring, diagnostics, and treatment. Abstract This review explores smart catheters as an emerging class of
Azra Yaprak Tarman +12 more
wiley +1 more source
At-home movement state classification using totally implantable cortical-basal ganglia neural interface. [PDF]
Ramesh R +5 more
europepmc +1 more source
A 3D flexible neural interface based on a microfluidic interconnection cable capable of chemical delivery. [PDF]
Kang YN +4 more
europepmc +1 more source
Boron‐Doped Nano‐Crystalline Coated Carbon Fibers for Phasic Dopamine Sensing
This uniform coating presents a mix of graphitic and diamond‐like carbon to create a mechanically and electrically robust alternative for the electrochemical detection of dopamine. The electrodes in this work possess the equivalent sensitivity to the state‐of‐the‐art FSCV dopamine detecting electrodes, whilst demonstrating an ability to withstand ...
Simon J. Higham +19 more
wiley +1 more source
A Bidirectional Neural Interface SoC With Adaptive IIR Stimulation Artifact Cancelers. [PDF]
Samiei A, Hashemi H.
europepmc +1 more source
Antimicrobial peptide (AMP)‐loaded nanocarriers provide a multifunctional strategy to combat drug‐resistant Mycobacterium tuberculosis. By enhancing intracellular delivery, bypassing efflux pumps, and disrupting bacterial membranes, this platform restores phagolysosome fusion and macrophage function.
Christian S. Carnero Canales +11 more
wiley +1 more source