Results 81 to 90 of about 5,081,374 (170)
Untersuchung des Dreipunkt – Neutral Point Clamped – Stromrichters mit Spannungszwischenkreis (3L-NPC-VSC) für Niederspannungswindkraftanwendungen [PDF]
Das Ziel der Arbeit war die Untersuchung eines neuartigen Phasenbausteins mit der Topologie des Dreipunkt – Neutral Point Clamped – Stromrichters mit Spannungszwischenkreis (3L-NPC-VSC) für Windkraftanwendungen.
Sprenger, Michael
core +2 more sources
A three‐level neutral point clamped (3L‐NPC) voltage source inverter (VSI) topology can be advantageous in electric vehicles with a high DC‐link voltage and a high switching frequency.
Serhat Emir Ogan, Emine Bostanci
doaj +1 more source
Model predictive control of three-level grid-connected inverters for weak power grids
In weak power grids, grid-connected inverters often suffer from poor robustness and significant harmonics. Moreover, model predictive control (MPC) heavily relies on system parameters, limiting its applicability in weak grids.
ZHAO Leilei +4 more
doaj +1 more source
This paper presents a comparative analysis of three-level (3L-NPC) and five-level (5L-NPC) Neutral-Point-Clamped converters using Finite Control Set Model Predictive Control (FCS-MPC) for reactive power compensation. The research addresses a critical gap
Oscar Paredes +11 more
doaj +1 more source
This paper presents a cascaded control strategy for neutral-point-clamped three-level (NPC-3L) inverter-fed permanent magnet synchronous motors (PMSMs), integrating continuous-control-set model-predictive control (CCS-MPC) with mid-point voltage ...
Zhenyan Liang +3 more
doaj +1 more source
Analytical and Experimental Investigation of Neutral Point Clamped Quasi-Impedance-Source Inverter
In this paper a new modification of a three-level neutral-point-clamped inverter is presented. The proposed topology combines the advantages of the three-level neutral-point-clamped full-bridge inverter with those of the quasi-impedance-source inverter ...
Ott, Silver +3 more
core
Loss estimation is a critical aspect of inverter design.The present work investigates the losses occurring in the DC-link capacitors of the three-phase three-level neutral point clamped and cascaded H-Bridge inverter topologies, by performing a harmonic ...
Sharkh, S. M. +2 more
core +1 more source
Z-source Neutral Point Clamped (NPC) inverters were introduced to integrate both the advantages of Z-source inverters and NPC inverters. However, traditional Z-source inverters suffer from high voltage stress and chopping input current.
Loh, Poh Chiang +5 more
core +1 more source
This study proposes a receiving-end voltage compensation method employing a phase-specific reactive power control strategy with a neutral-point-clamped (NPC) inverter in a three-phase four-wire distribution system. The principle of the proposed receiving
Yuka Sabi, Hiroaki Yamada