Results 181 to 190 of about 28,259 (261)

Biomechanics of the implant‐supported full arch fixed complete denture manufactured by milling and injection techniques: An experimental and FEA study

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose This study aims to characterize the mechanical properties of implant‐supported full arch fixed complete dentures manufactured by milling and injection techniques. Materials and Methods Twenty‐two samples with milling and injection manufacturing techniques were fabricated.
Mustafa Gürkan   +7 more
wiley   +1 more source

Effect of substructure fabrication method and design on the fracture resistance properties of metal–ceramic restorations

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose In metal–ceramic restorations, the substructure fabrication method and design may affect the prognosis of the prosthesis. This study evaluated and compared the fracture resistance of metal–ceramic restorations fabricated with different substructure fabrication methods using two different alloy powders and designs.
Young‐Hoon Lee   +4 more
wiley   +1 more source

From Bench Testing to Virtual Implantation: A Comparative Study Between Poly-l-Lactic Acid and Nickel-Titanium Braided Stents. [PDF]

open access: yesInt J Numer Method Biomed Eng
Lucchetti A   +7 more
europepmc   +1 more source

Comparative Evaluation of Treatment Effectiveness in Skeletal Class III Malocclusion: Surgery‐First Approach Using Clear Aligners Versus Fixed Appliances

open access: yesOrthodontics &Craniofacial Research, EarlyView.
ABSTRACT Objective This study aimed to assess treatment outcomes, identify predictors of relapse in skeletal Class III patients treated with the surgery‐first approach (SFA), comparing fixed appliances (FA) with invisalign clear aligners (CA). Materials and Methods Forty adult patients treated with bimaxillary surgery and SFA were retrospectively ...
Yang Zhou   +3 more
wiley   +1 more source

Magnetic Resonance Imaging Safety in Patients With Conditional Mixed‐Manufacturer Devices

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Background Magnetic resonance imaging (MRI) is a critical diagnostic tool known for its non‐invasive nature and high‐resolution imaging capabilities. However, its safety in patients with cardiac implantable electronic devices (CIEDs), particularly those with mixed‐lead systems, remains a significant clinical concern.
Ryka M. Tashakkor   +5 more
wiley   +1 more source

Inflammation and mechanical force‐induced bone remodeling

open access: yesPeriodontology 2000, EarlyView.
Abstract Periodontitis arises from imbalanced host–microbe interactions, leading to dysbiosis and destructive inflammation. The host's innate and adaptive immune responses produce pro‐inflammatory mediators that stimulate destructive events, which cause loss of alveolar bone and connective tissue attachment.
Hyeran Helen Jeon   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy