Results 11 to 20 of about 28,445 (214)

Ocular Biocompatibility of a Nitinol Capsular Tension Ring (CTR)

open access: yesThe EuroBiotech Journal, 2022
Introduction: The biocompatibility of nitinol in the human body has extensively been demonstrated. Although nitinol is already being used for intraocular surgeries such as lens fragmentation and foreign body extraction, little is known about its ...
de Aragon Javier S Martinez   +2 more
doaj   +1 more source

Adhesion, vitality and osteogenic differentiation capacity of adipose derived stem cells seeded on nitinol nanoparticle coatings. [PDF]

open access: yesPLoS ONE, 2013
Autologous cells can be used for a bioactivation of osteoimplants to enhance osseointegration. In this regard, adipose derived stem cells (ASCs) offer interesting perspectives in implantology because they are fast and easy to isolate.
Sarah Strauss   +7 more
doaj   +1 more source

TiNi Alloy Lattice Structures with Negative Poisson’s Ratio: Computer Simulation and Experimental Results

open access: yesMetals, 2022
One of the issues that modern implants face is their high stiffness, coupled with a positive Poisson’s ratio along the implant. This creates certain problems with bone inflammation and implant detachment.
Eduard Farber   +6 more
doaj   +1 more source

The determination and evaluation of Nitinol constitutive models for finite element analysis [PDF]

open access: yes, 2007
Superelastic Ni-Ti (Nitinol) is a member of the shape memory alloy (SMA) family of metals. The physical properties of Nitinol are highly dependant on a number of factors, including manufacturing method, subsequent processing, operating temperature, and ...
Ashton, T.R.   +4 more
core   +1 more source

Development of hot drawing process for nitinol tube [PDF]

open access: yes, 2009
In recent years, Nitinol, near-equiatomic nickel-titanium alloys, have found growing applications in medical technology and joining technology, due to their special characteristics such as shape memory, superplasticity and biocompatibility.
Favier D.   +7 more
core   +2 more sources

A comparison of two configurations for a dual-resonance cymbal transducer [PDF]

open access: yes, 2018
The ability to design tuned ultrasonic devices that can be operated in the same mode at two different frequencies has the potential to benefit a range of applications, such as surgical cutting procedures where the penetration through soft then hard ...
Feeney, Andrew, Lucas, Margaret
core   +1 more source

Preparation of ROS‐Responsive Exosome Coating of Nitinol Material for Making the Neurointerventional Stent

open access: yesAdvanced Materials Interfaces, 2023
Nitinol (NiTi) alloy is an ideal material for preparing neurointerventional stents due to its excellent mechanical properties and biocompatibility. However, NiTi stents without surface‐specific functionalization cause a high rate of stent thrombosis and ...
Lin Duan   +10 more
doaj   +1 more source

Microstructure and Mechanical Properties of Dissimilar Friction Welding Ti-6Al-4V Alloy to Nitinol

open access: yesMetals, 2021
In the present study, a friction welding process was adopted to join dissimilar alloys of Ti-Al-4V to Nitinol. The effect of friction welding on the evolution of welded macro and microstructures and their hardnesses and tensile properties were studied ...
Ateekh Ur Rehman   +4 more
doaj   +1 more source

Experimental Investigation of Electropolishing in Ethylene Glycol-NaCl Electrolyte for Surface Integrity of Nitinol Cardiovascular Stents

open access: yesElectrochemistry, 2020
In order to improve the surface integrity of nitinol cardiovascular stents, this paper presented the method of electropolishing nitinol cardiovascular stents by adding distilled water of different concentration into ethylene glycol - sodium chloride ...
Xiaoyu SUN   +5 more
doaj   +1 more source

Evaluation of Mechanical and Physical Properties of Clinically Used and Recycled Superelastic NiTi Wires [PDF]

open access: yesJournal of Clinical and Diagnostic Research, 2016
Introduction: The initial leveling and aligning phase has been simplified with the introduction of superelastic nickel-titanium archwires. The relatively high cost of these wires has prompted some of the clinicians to reuse them after sterilization ...
Venkata Naidu Bavikati   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy