Results 61 to 70 of about 2,702 (149)
Analysis of the APR1400 Benchmark Using High-Fidelity Pin-Wise Core Calculation Codes
The KEPCO Nuclear Fuel Company (KNF) has undertaken considerable efforts to improve the KARMA/ASTRA nuclear design code system to meet the increasing demand for high-fidelity core analyses.
Hwanyeal Yu, Hyunsik Hong, Jooil Yoon
doaj +1 more source
Tracing Frame Trajectories in Policy Debates: Placing the EU in Global Discourse Networks
Abstract This special issue explores the evolving trajectories of policy frames in European and global public policy, emphasising the non‐linear processes through which frames emerge, diffuse and become salient or silenced over time. The contributions focus on how actors in governance, ranging from governments and international organisations to civil ...
Ece Özlem Atikcan +3 more
wiley +1 more source
Rod Ejection and Drop Accident Analysis of Aqueous Homogeneous Solution Reactor
Aqueous Homogeneous Solution Reactor concept has been proposed for producing medical isotopes (Medical Isotope Production Reactor-MIPR). However, there are several difficulties in transient calculation of aqueous homogeneous solution reactors.
Kunpeng Wang +5 more
doaj +1 more source
ABSTRACT Aims This systematic review assesses current evidence on the management of non‐plaque (dental biofilm)‐induced gingival diseases and conditions (NPIGDs), including (i) inflammatory and immune conditions, (ii) neoplasms and (iii) gingival pigmentations.
Maria Clotilde Carra +5 more
wiley +1 more source
ABSTRACT Polycentric governance is a trust‐intensive and trust‐dependent governance that should actively seek to build and restore trust. The different ways in which this is done are poorly understood. Our study of the environmental, social, and governance (ESG) strategies and the green transition clarifies the role of enhanced self‐regulation and ...
Agnieszka Smoleńska, David Levi‐Faur
wiley +1 more source
A conventional two-step approach of a transport calculation and a nodal diffusion calculation, such as CASMO/SIMULATE, APOLLO/SMART, was used in the light water reactor core design for decades.
ZHANG Bin;LI Qing;CAI Yun;LIU Kun;QIN Xue;WANG Shiqian;JI Wenhao;GUO Rui;ZHAO Chen;PENG Xingjie
doaj
Abstract figure legend Schematic overview of the experimental and computational framework for investigating hiPSC‐CM electrophysiology with MEA systems. The MEA‐based model integrates experimental data with phenotype‐specific ionic models and tissue‐level heterogeneity.
Sofia Botti +2 more
wiley +1 more source
Abstract figure legend Depolarization and repolarization duration analysis was conducted in preadolescent groups with IUGR and controls using a 12‐lead ECG. Principal component analysis was applied over the 12‐lead ECGs to generate spatially transformed leads better suited for robust ECG fiducial points detection.
Freddy L. Bueno‐Palomeque +5 more
wiley +1 more source
Hypoxia and hypercapnia elicit overlapping but distinct skeletal muscle toxicities
Abstract figure legend Hypoxia and hypercapnia cause overlapping skeletal muscle phenotypes, including atrophy, change in myofibre metabolic profile and myogenic response to injury. Both signals operate via distinct cellular pathways. Abstract Skeletal muscle dysfunction is strongly associated with elevated mortality in acute and chronic pulmonary ...
Joseph Balnis, Ariel Jaitovich
wiley +1 more source
What's new? Esophageal adenocarcinoma (EAC) is an aggressive cancer with poor survival and variable response to perioperative chemotherapy. Although histopathological features correlate with outcomes, the relationship specifically between adherens junction (AJ) protein expression and treatment response in EAC remains uncertain.
Bastian Grothey +8 more
wiley +1 more source

