Results 171 to 180 of about 9,216,494 (260)
An all‐in‐one analog AI accelerator is presented, enabling on‐chip training, weight retention, and long‐term inference acceleration. It leverages a BEOL‐integrated CMO/HfOx ReRAM array with low‐voltage operation (<1.5 V), multi‐bit capability over 32 states, low programming noise (10 nS), and near‐ideal weight transfer.
Donato Francesco Falcone +11 more
wiley +1 more source
A Scoping Review: The Effect of Anthropogenic Noise on Animal Welfare in Zoological Settings. [PDF]
Kruse TN, Flint M.
europepmc +1 more source
Edible electronics needs integrated logic circuits for computation and control. This work presents a potentially edible printed chitosan‐gated transistor with a design optimized for integration in circuits. Its implementation in integrated logic gates and circuits operating at low voltage (0.7 V) is demonstrated, as well as the compatibility with an ...
Giulia Coco +8 more
wiley +1 more source
Loose Particle Material Identification for Sealed Electronic Devices Using Pulse Endpoint Detection and CEEMDAN Feature Optimization. [PDF]
Ren Z, Wang K, Lu Y, Song S, Zou X.
europepmc +1 more source
ABSTRACT Chitosan, a polysaccharide upcycled from biowaste, has long promised sustainable, biocompatible, and antimicrobial films and devices, an appeal reinforced by its recent regulatory recognition, with several chitosan‐based antibacterial dressings gaining clearance through the Food and Drug Administration's 510(k) pathway.
Jacopo Nicoletti +16 more
wiley +1 more source
Graphene-nanodiamond membranes for atomic-impact sensing: design and fluorescence readout limits. [PDF]
Fiedler J, Eder SD, Zalieckas J.
europepmc +1 more source
A soft, dual‐channel hydrogel patch enables simultaneous detection of wound temperature and strain by integrating ion‐diffusion‐mediated thermoelectric and resistive sensing. The conformal design maintains stable performance during motion, capturing subtle inflammatory and mechanical changes for continuous wound monitoring.
Yu Fang +7 more
wiley +1 more source
Multi-Sensor Mobile Laser Doppler Vibrometry for Internal Damage Detection in Reinforced Concrete Structures. [PDF]
Liang S, Zhang D.
europepmc +1 more source
Ferroelectric tunnel junction devices based on epitaxial undoped ferroelectric HfO2 films demonstrate stable switching endurance of over 106 switching cycles, low write voltages of ±3 V, 16 measured resistance states, and neuromorphic capability.
Markus Hellenbrand +13 more
wiley +1 more source
The Big Bang: How Does Indoor Noise Affect Lifestyle Choices of Older Community-Dwelling Adults? An Exploratory Mixed Methods Study. [PDF]
Short A +4 more
europepmc +1 more source

