Results 271 to 280 of about 438,791 (295)
Some of the next articles are maybe not open access.
Non-contact bias voltage measurement using the electro-optic probing technique
Measurement Science and Technology, 2008The traditional non-contact electro-optic (EO) probing technique is further extended to measure quasi-dc bias voltages. We propose a special external LiTaO3 probe equipped with a grounded side-electrode (GSE) and a power supply modulation (PSM) method.
Wen-Kai Kuo +3 more
openaire +1 more source
A Novel Non-contact Capacitive Probe for Common-Mode Voltage Measurement
IEICE Transactions on Communications, 2007This paper describes a capacitive voltage probe (CVP) that can measure a common-mode voltage on a cable without touching its conductor. This CVP has two coaxial electrodes: the inner electrode works as a voltage pickup and the outer one shields the inner electrode. These electrodes separate into two parts for clamping to the cable.
R. KOBAYASHI +5 more
openaire +1 more source
Study of Non-Contact and Non-Ground Voltage Signal Measurement System in Medium Voltage
IEEE Latin America Transactions, 2018The measurement of current and voltage (as well as the indexes derived from them) in the electricity distribution network becomes more and more necessary in the present day. The power concessionaires seek to distribute to their customers, reliability and stability in the supply of this energy with admissible levels of quality established by the ...
Ederson Paulo Vogel +1 more
openaire +1 more source
2024 4th International Conference on Smart Grid and Energy Internet (SGEI)
Transient overvoltage in power systems, caused by lightning or switching, are a critical reliability constraint. Traditional contact measurement methods have limitations, prompting the development of non-contact measurement technologies.
Yongsen Sun +5 more
semanticscholar +1 more source
Transient overvoltage in power systems, caused by lightning or switching, are a critical reliability constraint. Traditional contact measurement methods have limitations, prompting the development of non-contact measurement technologies.
Yongsen Sun +5 more
semanticscholar +1 more source
Non-contact transient high-voltage measurement with self-integrating D-dot probe
International Journal of Applied Electromagnetics and Mechanics, 2015Online transformer monitoring and protective relaying require voltage sensors with fast response and high precision. Traditional devices, such as resistive and capacitive dividers, have disadvantages in measuring transient voltage, e.g., oscillation, narrow bandwidth, and large size.
Wang, Jingang, Yang, Jie, Luo, Ruixi
openaire +1 more source
IEEE Transactions on Instrumentation and Measurement
With increasing requirements for online monitoring of overhead transmission lines (OTLs) in smart grids, contact-free measurement technologies have been updated these decades.
Y. Xing +4 more
semanticscholar +1 more source
With increasing requirements for online monitoring of overhead transmission lines (OTLs) in smart grids, contact-free measurement technologies have been updated these decades.
Y. Xing +4 more
semanticscholar +1 more source
International journal of circuit theory and applications
Monitoring electric power systems is essential for avoiding disruptions, improving efficiency, and detecting faults. Traditional methods involve interrupting the power lines and pose safety risks.
R. Colella +2 more
semanticscholar +1 more source
Monitoring electric power systems is essential for avoiding disruptions, improving efficiency, and detecting faults. Traditional methods involve interrupting the power lines and pose safety risks.
R. Colella +2 more
semanticscholar +1 more source
IEEE International Conference on High Voltage Engineering and Application
In order to solve the problems of low precision and difficult installation of grid broadband voltage measurement, this paper proposes a non-contact measurement method of broadband voltage reconstruction by leakage current.
Hui Feng +3 more
semanticscholar +1 more source
In order to solve the problems of low precision and difficult installation of grid broadband voltage measurement, this paper proposes a non-contact measurement method of broadband voltage reconstruction by leakage current.
Hui Feng +3 more
semanticscholar +1 more source
A Non-Contact Transient Voltage Inference Method Based on Multi-Fidelity Data Fusion
IEEE Transactions on Instrumentation and MeasurementThe development of power systems requires advanced technologies for transient voltage measurement. In non-contact measurement, accurately determining the coupling parameters between the sensor and the measured conductor is critical.
Yichi Li +5 more
semanticscholar +1 more source
Research on Synchronous Measurement Methods Based on Non-Contact Sensing
2024 IEEE 2nd International Conference on Power Science and Technology (ICPST)Non-contact sensing technology is increasingly gaining attention for its benefits of ease of installation, cost-effectiveness, and flexibility. This study introduces a non-contact synchronous phasor measurement technology, tailored for areas with high ...
Tianyu Wang, Hao Liu
semanticscholar +1 more source

