Results 141 to 150 of about 12,592,140 (253)
Here, we present a textile, wearable capacitive interface enabling multidirectional remote control by dynamically modulating electrode overlap and spacing via a freely gliding upper electrode. A forearm‐mounted prototype drives robotic and media tasks with 12–15 ms latency, maintains < 0.8% drift after 500 cycles, and remains stably functional at 90 ...
Cagatay Gumus +8 more
wiley +1 more source
Flexible Sensors for Robotics Tactile Perception: A Review
Flexible tactile sensing for robotics is reviewed through four interconnected dimensions. Physical mechanisms include piezoresistive, capacitive, piezoelectric, triboelectric, iontronic, and optical sensing. Structural design includes bioinspired, defect‐based, and MEMS‐based tactile systems.
Yu Song, Ying Chen, Yihao Chen, Xue Feng
wiley +1 more source
A Transnasal Endoscope for Robotically Assisted Gastroscopy
This work introduces a 4.25 mm diameter magnetically navigated transnasal endoscope for upper gastrointestinal (GI) screening and intervention. The system enables precise remote steering throughout the upper GI tract and is demonstrated through in vitro and in vivo experiments, including the robotic execution of preprogrammed retroflexions, trans ...
Alexandre Mesot +6 more
wiley +1 more source
Convolutional Sparse Modular Fusion Algorithm for Non-Rigid Registration of Visible–Infrared Images
Existing image fusion algorithms involve extensive models and high computational demands when processing source images that require non-rigid registration, which may not align with the practical needs of engineering applications. To tackle this challenge,
Tao Luo +4 more
doaj +1 more source
Shear‐Isolating Actuation System for Exosuit Using Movable Pulley With Webbing‐Driven Mechanism
Tendon‐driven exosuits can chafe the skin because the moving tendon slides against the wearer. A shear‐isolating actuation system combining a movable pulley with flat‐profile webbing keeps the body‐contacting tendon layer stationary, relocating relative motion away from the skin. The compact 145‐g actuator delivers 150 N of assistance, and benchtop and
Kyeongmin Lim +5 more
wiley +1 more source
A balanced multimodal food‐waste dataset and a novel Split Spatial‐Spectral Attention fusion framework are presented for robotic contaminant detection. Separate processing of RGB, thermal, and multispectral inputs preserves subtle material signatures before feature integration, reducing modality interference and improving classification and ...
Matthew Vestal +5 more
wiley +1 more source
Introduction to the Non-rigid Image Registration Evaluation Project (NIREP)
Non-rigid image registration (NIR) is an essential tool for morphologic comparisons in the presence of intra- and inter-individual anatomic variations. Many NIR methods have been developed, but are especially difficult to evaluate since point-wise inter ...
Pirwani, IA +17 more
core +1 more source
This review brings together 20 publications describing 11 robotic system families developed for instrument handling, sterile‐package opening, supply delivery, and operating room logistics. Perception is becoming more capable through deep learning and language‐guided control, but autonomy remains limited, evidence is largely laboratory‐based, and no ...
Eugenia Mawuenya Akpo +4 more
wiley +1 more source
Robotics in Ionizing Radiation Environments: Vulnerabilities, Hardening, and Future Directions
Radiation exposure causes cumulative degradation in robotic sensors, actuators, and electronic logic, often leading to undetected failures. This study maps component vulnerabilities, evaluates hardening and shielding strategies, and identifies testing gaps that must be addressed to enable next‐generation radiation‐tolerant robotic systems.
Francis A. K. Djirackor +4 more
wiley +1 more source
The PALPABLE minimally invasive surgery (MIS) stiffness mapping tool is a novel optical fiber instrument designed for real‐time soft‐tissue stiffness mapping in MIS. By independently measuring tissue indentation depth alongside force magnitude and direction, this handheld device can detect embedded hard inclusions at depths down to 12.5 mm.
Georgios Violakis +10 more
wiley +1 more source

