Results 241 to 250 of about 10,144,462 (296)
Some of the next articles are maybe not open access.

Holographic interferometry of non-sinusoidal vibrations

Opto-electronics, 1974
In this paper, the techniques of extended pulse stroboscopic holography and holographic subtraction have been applied to the study of periodic, non-sinusoidal vibrations represented by a Jacobian elliptic function. Fringe irradiance distribution in reconstructed images has been evaluated for the two cases.
P. C. Gupta, K. Singh
openaire   +1 more source

On the Definition of Reactive Power Under Non-Sinusoidal Conditions

IEEE Transactions on Power Apparatus and Systems, 1980
A new method of defining reactive power under non- sinusoidal conditions is proposed. It consists of sub- dividing the current into components which would have the same waveform as the current in a resistance and either an inductance or a capacitance when the voltage is applied to them, and into a residual component.
Kusters, N. L., Moore, W. J.M.
openaire   +2 more sources

Induction Motor Operation With Non-Sinusoidal Impressed Voltages

Transactions of the American Institute of Electrical Engineers, 1929
The usual procedure in considering the operation of induction motors has been to neglect the effect of harmonics. Although in most instances this gives results which are sufficiently accurate, the question of how much these effects are or how much is being neglected has yet to be answered in electrical engineering literature.
L. A. Doggett, E. R. Queer
openaire   +1 more source

An evaluation of non-sinusoidal tariff schemes towards a regulatory tariff system for non-sinusoidal power system conditions

2004 IEEE Africon. 7th Africon Conference in Africa (IEEE Cat. No.04CH37590), 2005
Harmonic distortion on the power system is a modern concern due to the technological advances in silicon technology and it presents an increased non-linear loading of the power system. The effects of harmonics are well known: customers could experience major production losses due to the loss of supply, for example; on the other hand, harmonic load ...
S.L. Bezuidenhout, A.P.J. Rens
openaire   +1 more source

Measurements for the characterization of passive components in non-sinusoidal conditions

IEEE Transactions on Instrumentation and Measurement, 2002
The paper deals with the measurement of R, L, C parameters of passive component in non-sinusoidal conditions. An innovative virtual instrument, implementing a measurement method based on system identification techniques, was realized to be used for the characterization of passive components in arbitrary conditions.
L. FERRIGNO   +2 more
openaire   +6 more sources

Factors Affecting Losses in Induction Motors with Non-Sinusoidal Supply

2007 IEEE Industry Applications Annual Meeting, 2007
This paper presents the results of an investigation into the factors affecting losses in induction motors operating with non-sinusoidal supply. It is well known that the losses in machines increase when a non-sinusoidal supply is used. However, the specific causes of the increase in loss and resultant techniques required to mitigate these losses are ...
BOGLIETTI, Aldo   +3 more
openaire   +3 more sources

Non-sinusoidal magnetisation and applications

2019
The book chapter shows that it is rare for soft magnetic materials in a.c. applications to be subject to perfectly sinusoidal flux-density waveforms. The designers and users of electrical machines are placing increasing demands on the magnetic cores. Traditionally, the electrical steels used in these devices are characterised under standard conditions ...
openaire   +1 more source

Derating of transformers under non-sinusoidal loads

2008 11th International Conference on Optimization of Electrical and Electronic Equipment, 2008
Transformers are normally designed and built for utilizing at rated frequency and prefect sinusoidal loads. Supplying non-linear loads by transformer leads to higher losses, early fatigue of insulation, and reduction of the useful life of transformer. To prevent these problems rated capacity of transformer supplying non-linear loads must be reduced. In
S.B. Sadati   +3 more
openaire   +1 more source

An Optical Fibre Sensor for Non-sinusoidal Current

IETE Journal of Research, 1997
Measurement of current and voltage in high voltage systems employing optical fibre sensors is becoming increasingly popular as the problem of insulation is practically eliminated. Vibrations, physical and acoustic, perturb the polarisation-preserving sensing fibre and cause added noise much in excess of the signal.
H O Modi, V Jagadeesh Kumar, P Sankaran
openaire   +1 more source

Non-sinusoidal Orthogonal Functions in Systems and Control

2016
This chapter discusses different types of non-sinusoidal orthogonal functions such as Haar functions, Walsh functions, block pulse functions, sample-and-hold functions, triangular functions, non-optimal block pulse functions and a few others. It also discusses briefly the application of Walsh, block pulse and triangular functions, three major members ...
Anish Deb   +2 more
openaire   +1 more source

Home - About - Disclaimer - Privacy