Results 1 to 10 of about 781,232 (282)
Improved Three-Phase AFD Islanding Detection Based on Digital Control and Non-Detection Zone Elimination [PDF]
This paper proposes an improved active frequency drift (AFD) islanding detection method of a three-phase inverter. Different than the existing single-phase AFD method, in the three-phase system, the disturbance is added to the phase angle, which takes ...
Xinxin Zheng +3 more
doaj +4 more sources
In this paper, a new and efficient passive islanding detection technique for a grid-connected hybrid distributed generating system has been proposed using Second Generation Wavelet Transform (SGWT) and Maximum Overlap Discrete Wavelet Transform (MODWT ...
B. Pangedaiah +4 more
doaj +4 more sources
Modified Q–f Droop Curve Method for Islanding Detection With Zero Non-Detection Zone [PDF]
In this paper, a modified Q-f droop curve method for the inverter-based distributed generator is proposed. The proposed method has merits such as detecting islanding with zero non-detection zone, negligible effects on power quality, and simple ...
Kianoush Naraghipour +3 more
doaj +5 more sources
Automatic non-volcanic tremor detection in the Mexican subduction zone [PDF]
Desarrollo de un algoritmo de detección de tremores no-volcánicos (TNV). Un TNV ocurre en el rango de frecuencia de 1 – 10 Hz, pero el ruido ambiental alto ocurre por encima de los 2 Hz en muchas de las estaciones del MesoAmerican Seismic Experiment ...
Allen Husker +3 more
doaj +5 more sources
A Novel Islanding Detection Scheme without Non Detection Zone
Unintentional islanding results in safety hazards, reliability, and many other issues. Therefore, the islanding detection of a power conditioning system of a distributed generation, such as a grid-connected photovoltaic inverter, is a key function for standard compliance.
Yeong-Min Jo +6 more
openaire +4 more sources
A Survey of Islanding Detection Methods for Microgrids and Assessment of Non-Detection Zones in Comparison with Grid Codes [PDF]
Detection of unintentional islanding is critical in microgrids in order to guarantee personal safety and avoid equipment damage. Most islanding detection techniques are based on monitoring and detecting abnormalities in magnitudes such as frequency ...
José Antonio Cebollero +4 more
doaj +4 more sources
A simple technique for islanding detection with negligible non-detection zone [PDF]
Although active islanding detection techniques have smaller nondetection zones than passive techniques, active methods could degrade the system power quality and are not as simple and easy to implement as passive methods. The islanding detection strategy, proposed in this paper, combines the advantages of both active and passive islanding detection ...
H.H. Zeineldin, J.L. Kirtley
openaire +4 more sources
This article proposes a fast and reliable two-level islanding detection method (IDM) for grid-connected photovoltaic system (GCPVS)-based microgrid. In the first level of the proposed IDM, the magnitude of the rate of change of output voltage (ROCOV) is computed.
Reza Bakhshi-Jafarabadi +3 more
openaire +6 more sources
Active islanding detection techniques majorly affect power quality due to injected harmonic signals, whereas passive methods have a large non-detection zone (NDZ).
Sareddy Venkata Rami Reddy +4 more
doaj +1 more source
The protection against the unintentional islanding of Grid-Tied inverters is an important electrical security issue addressed by the main Standards. This concern is justified in face of the fact that unintentional islanding can lead to abrupt variations ...
Ênio Costa Resende +2 more
doaj +1 more source