Results 271 to 280 of about 781,232 (282)
Some of the next articles are maybe not open access.
CIRED 2012 Workshop: Integration of Renewables into the Distribution Grid, 2012
Loss of mains protection (LOM) is among the most challenging issues related to the integration of distributed generation (DG). This paper presents simulation studies on the effect of multiple DG units on LOM protection. The results reveal an operational risk related to the active LOM detection methods.
Mäkinen Anssi +3 more
openaire +1 more source
Loss of mains protection (LOM) is among the most challenging issues related to the integration of distributed generation (DG). This paper presents simulation studies on the effect of multiple DG units on LOM protection. The results reveal an operational risk related to the active LOM detection methods.
Mäkinen Anssi +3 more
openaire +1 more source
Local Parameter-Based Islanding Detection in DC Microgrid With Zero Non-Detection Zone
IEEE Transactions on Industry Applications, 2022Sunil Kumar Maurya +2 more
openaire +1 more source
IECON 2007 - 33rd Annual Conference of the IEEE Industrial Electronics Society, 2007
The islanding effect of utility-interactive photovoltaic (UIPV) system may cause hazards for the grid equipment, and even danger to grid personnel. Therefore, reliable islanding detection is one of the crucial factors to connect grid for UIPV system. Over the years, a number of research works have been concentrated on the techniques of non-detection ...
Hui Wang +4 more
openaire +1 more source
The islanding effect of utility-interactive photovoltaic (UIPV) system may cause hazards for the grid equipment, and even danger to grid personnel. Therefore, reliable islanding detection is one of the crucial factors to connect grid for UIPV system. Over the years, a number of research works have been concentrated on the techniques of non-detection ...
Hui Wang +4 more
openaire +1 more source
Instability criterion to eliminate the Non-Detection Zone of the Sandia Frequency Shift method
2009 IEEE/PES Power Systems Conference and Exposition, 2009Sandia Frequency Shift (SFS) islanding detection method is considered amongst the most efficient islanding detection methods that possesses small Non-Detection Zone (NDZ) for inverter based Distributed Generation (DG). The NDZ of the SFS depends to a great extent on its design parameters.
H. H. Zeineldin, S. Kennedy
openaire +1 more source
2009 Pacific-Asia Conference on Circuits, Communications and Systems, 2009
Islanding detection and protection is an important concern for grid connected photovoltaic (PV) power generation system due to personnel and equipment safety. Over/Under Voltage Protection (OVP/UVP) and Over/Under Frequency Protection (OFP/UFP) are basical inverter resident passive islanding detection method (IDM) for detecting an islanding condition ...
Zengqiang Mi, Fei Wang
openaire +1 more source
Islanding detection and protection is an important concern for grid connected photovoltaic (PV) power generation system due to personnel and equipment safety. Over/Under Voltage Protection (OVP/UVP) and Over/Under Frequency Protection (OFP/UFP) are basical inverter resident passive islanding detection method (IDM) for detecting an islanding condition ...
Zengqiang Mi, Fei Wang
openaire +1 more source
Non-Detection Zone Analysis of Frequency and Voltage Based Passive Methods
2022 2nd Odisha International Conference on Electrical Power Engineering, Communication and Computing Technology (ODICON), 2022Plaban Dash, M. Mishra
openaire +1 more source
Modified Q–f Droop Curve Method for Islanding Detection With Zero Non-Detection Zone
IEEE Access, 2021Kianoush Naraghipour +2 more
exaly
International Transactions on Electrical Energy Systems, 2016
Farid Hashemi, Mohammad Mohammadi
exaly
Farid Hashemi, Mohammad Mohammadi
exaly

