Results 151 to 160 of about 97,324 (284)

Enhanced Self‐Phase Modulation in Silicon Nitride Waveguides Integrated With 2D MoS2 Films

open access: yesAdvanced Materials Technologies, EarlyView.
ABSTRACT On‐chip integration of 2D materials provides a promising route toward next‐generation integrated optical devices with performance beyond existing limits. Here, significantly enhanced spectral broadening induced by self‐phase modulation (SPM) is experimentally demonstrated in silicon nitride (Si3N4) waveguides integrated with 2D monolayer ...
Shahaz S. Hameed   +15 more
wiley   +1 more source

Highly Anisotropic Quasi‐Direct Organic Metal Halide Hybrids: A Platform for Polarization‐Sensitive Optoelectronics

open access: yesAdvanced Materials Technologies, EarlyView.
One‐dimensional C4N2H14PbBr4 is shown to have a quasi‐direct electronic band structure and strongly anisotropic transport with polarized broadband emission. A GW/Bethe–Salpeter excited‐state force formalism, supported by polarized Raman and temperature‐dependent photoluminescence, identifies low–frequency Pb–Br phonons that drive ultrafast exciton self‐
Rijan Karkee   +7 more
wiley   +1 more source

Scaling digital models. [PDF]

open access: yesSci Rep
Karanfil D, Ravani B.
europepmc   +1 more source

A Pressure Microsensor Made of Parylene‐C for Use as Medical Implant

open access: yesAdvanced Materials Technologies, EarlyView.
A monolithic parylene‐C pressure sensor with gold strain gauges provides 6.2 μV$\mu{\rm V}$·mmHg$\cdot{\rm mmHg}$−1$^{-1}$ sensitivity. The morphology of a sputtered thin film strain sensor is granular/columnar, which results in a high gauge factor of 7.5. Thermal bonding and parylene‐C coating create a hermetic cavity.
Ann‐Kathrin Klein   +2 more
wiley   +1 more source

Cap‐oPMN: Oral Inflammatory Load Quantification Using Capillary Microfluidics and Automated Image Processing

open access: yesAdvanced Materials Technologies, EarlyView.
ABSTRACT Quantifying oral polymorphonuclear neutrophils (oPMNs) is a clinically validated approach for assessing periodontal inflammation. However, current methods, such as manual hemocytometry and flow cytometry, are time‐consuming (>3 h), require invasive sampling, and depend on staining and complex instrumentation, making them unsuitable for point ...
Mohsen Hassani   +9 more
wiley   +1 more source

Tunable Extraordinary Optical Transmission in the Long‐Wavelength Infrared Range Using Electrostatic MEMS Actuation

open access: yesAdvanced Materials Technologies, EarlyView.
A MEMS‐integrated metamaterial filter enables continuous, low‐voltage spectral tuning in the long‐wavelength infrared (LWIR). The device employs extraordinary optical transmission in a dual suspended metasurface stack, where electrostatic actuation precisely controls the intermembrane air gap.
Oleg Bannik   +6 more
wiley   +1 more source

Bidirectional Process Prediction in the Laser‐Induced‐Graphene Production Using Blackbox Deep Learning

open access: yesAdvanced Materials Technologies, EarlyView.
This study shows that a lightweight blackbox neural network provides a practical, cost‐effective solution for bidirectional process prediction in laser‐induced graphene (LIG) fabrication. Achieving high predictive performance with minimal overhead, the approach democratizes machine learning (ML) for resource‐limited environments.
Maxim Polomoshnov   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy