Results 31 to 40 of about 6,061 (168)
Descemet membrane detachment after nonpenetrating filtering surgery.
To make surgeons performing nonpenetrating filtering surgery aware of an unusual complication namely Descemet membrane detachment. We retrospectively reviewed nine eyes of nine patients seen in our hospital with Descemet membrane detachment occurring ...
Ravinet, E. +6 more
core +1 more source
Nonpenetrating glaucoma surgery: Meta-analysis of recent results
Purpose: To evaluate the efficacy of nonpenetrating glaucoma surgery for open angle glaucoma with respect to target intraocular pressure (IOP) and severity of ...
Hondur, AHMET MURAD +2 more
core +1 more source
20.500.12530/87896XEN gel stent and nonpenetrating deep sclerectomy, both either alone or in combination with cataract surgery, significantly lowered the intraocular pressure (IOP) and reduced the number of antiglaucoma medications in patients with open ...
Martín-Giral, Elena +13 more
core +1 more source
Objective. To report the 15-year trend in ophthalmic presentations to the emergency department (ED) at the only medical center in Lebanon that provides 24-hour ophthalmologic care. Methods.
Haytham I. Salti +10 more
doaj +1 more source
Nonpenetrating stapling: A valuable alternative for coronary anastomoses?
Background. The safe development of minimally invasive coronary artery bypass operations might require alternatives to conventional suture-based anastomotic techniques.
Perrault, LP +6 more
core +1 more source
A continuous murmur following a nonpenetrating chest trauma
We reported a rare case of non-penetrating chest trauma-induced fistula from the right sinus of Valsalva to the right heart chambers. The ruptured sinus of Valsalva aneurysm was diagnosed preoperatively and operated on successfully.
Salma Charfeddine +7 more
doaj +1 more source
Abstract Corneal reconstruction is a key part of veterinary ophthalmic practice and numerous reconstructive techniques have been described for use in small animals in the peer‐reviewed veterinary literature written in English. Despite the evidence accrued over the last six decades in over 40 clinical articles and numerous other publications on ocular ...
Rick F. Sanchez +2 more
wiley +1 more source
A comparison of para-anastomotic compliance profiles after vascular anastomosis: Nonpenetrating clips versus standard sutures [PDF]
Purpose: Anastomotic compliance is an important predictive factor for long-term patency of small diameter vascular reconstruction. In this experimental study we compare the compliance of continuous and interrupted sutured vascular anastomoses with those ...
Hamilton, George +11 more
core +1 more source
Automated stereological methods are presented for approximating the 3D size distribution of unimodal or bimodal precipitate dispersions considering 2D and 1D measurements taken from polydisperse spherical non-penetrating particle dispersions. A method to
Magnus J. Anderson, Hector C. Basoalto
doaj +1 more source
Abstract In recent years, the clinical treatment and symptom management of neurological disorders have faced significant challenges due to the high complexity of the nervous system's structure and function. Against this backdrop, physical stimulation techniques have emerged as a vital complementary approach to traditional pharmacological treatments and
Wanying Li, Liqun Chen
wiley +1 more source

