Results 91 to 100 of about 2,728,162 (325)
Applications of KP Nuclear Parton Distributions [PDF]
We review the nuclear parton distribution functions computed on the basis of our microscopic model taking into account a number of nuclear effects including Fermi motion and nuclear binding, nuclear meson-exchange currents, off-shell corrections to bound nucleon distributions and nuclear shadowing.
arxiv
Multi‐institutional study on image quality for a novel CBCT solution on O‐ring linac
Abstract Introduction This work presents a multi‐institutional study on image quality provided by a novel cone beam computed tomography (CBCT). The main goal is to investigate the consistency of imaging performance across multiple institutions.
Luis Agulles‐Pedrós+11 more
wiley +1 more source
The neutron capture cross section of $$ ^{181} $$ 181 Ta is relevant to s-process of nuclear astrophysics, extraterrestrial samples analysis in planetary geology and new generation nuclear energy system design. The $$^{181}$$ 181 Ta( $$n,\gamma $$ n , γ )
Zhendong An+50 more
doaj +1 more source
Abstract This study aimed to evaluate the dose‐exposure reduction effect of a crystalline lens with a bismuth eye shield using cone‐beam computed tomography (CBCT) for head image‐guided radiation therapy. The ocular surface dose of the head phantom (THRA‐1) is defined as a crystalline lens exposure dose and is measured using a radiophotoluminescence ...
Tatsuya Yoshida+5 more
wiley +1 more source
Nuclear Physics and Lattice QCD [PDF]
Lattice QCD is progressing toward being able to impact our understanding of nuclei and nuclear processes. I discuss areas of nuclear physics that are becoming possible to explore with lattice QCD, the techniques that are currently available and the status of numerical explorations.
arxiv
Abstract The thermoluminescence dosimeter (TLD) sheet is a measurement device coated with manganese‐doped LiB3O5 in sheet form. The sheet is 0.2‐mm thick and flexible. Hence, it can fit and be installed on irregular surfaces. The current study aimed to evaluate the feasibility of measuring patient surface doses during radiation therapy using TLD sheets.
Yuya Miyasaka+8 more
wiley +1 more source
Abstract Purpose Single‐isocenter multitarget (SIMT) radiosurgery has become increasingly popular as advancement in planning and delivery systems have made this approach clinically viable. With targets varying in size and distance from isocenter, SIMT plans are highly complex with dynamic multileaf collimator (MLC) motion.
Hem Moktan+3 more
wiley +1 more source
Dose rate correction of a diode array for universal wedge field dosimetric verification
Abstract Purpose To study the performance of MapCHECK 3 (MC3) in measuring universal wedge fields and propose a dose rate correction strategy to improve MC3 measurement accuracy. Materials and methods Universal wedge fields with different wedge angles and field sizes were measured at different depths using MC3.
Linyi Shen+6 more
wiley +1 more source
Monte Carlo modeling of radiation dose from radiation therapy with superficial x‐rays
Abstract Introduction Superficial x‐rays (50–100 kVp) are used for treating non‐melanoma skin cancer and intraoperative radiation therapy (IORT). At these energies, the photoelectric effect significantly increases absorbed dose to bone compared to soft tissue.
Reham Barghash+3 more
wiley +1 more source
Abstract Purpose This study evaluates the dosimetric and geometric precision of a virtual cone technique using CBCT‐based polymer gel dosimetry, enabling radiation delivery, and imaging readout within an identical spatial coordinate system. Methods We created a C# script for a virtual cone technique that generates a treatment plan with 10 gantry arcs ...
Tenzin Kunkyab+6 more
wiley +1 more source