Results 91 to 100 of about 2,728,162 (325)

Applications of KP Nuclear Parton Distributions [PDF]

open access: yesPoS DIS2016 (2016) 027, 2016
We review the nuclear parton distribution functions computed on the basis of our microscopic model taking into account a number of nuclear effects including Fermi motion and nuclear binding, nuclear meson-exchange currents, off-shell corrections to bound nucleon distributions and nuclear shadowing.
arxiv  

Multi‐institutional study on image quality for a novel CBCT solution on O‐ring linac

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Introduction This work presents a multi‐institutional study on image quality provided by a novel cone beam computed tomography (CBCT). The main goal is to investigate the consistency of imaging performance across multiple institutions.
Luis Agulles‐Pedrós   +11 more
wiley   +1 more source

Measurement of the $$ ^{181} $$ 181 Ta( $$n,\gamma $$ n , γ ) cross sections up to stellar s-process temperatures at the CSNS Back-n

open access: yesScientific Reports, 2023
The neutron capture cross section of $$ ^{181} $$ 181 Ta is relevant to s-process of nuclear astrophysics, extraterrestrial samples analysis in planetary geology and new generation nuclear energy system design. The $$^{181}$$ 181 Ta( $$n,\gamma $$ n , γ )
Zhendong An   +50 more
doaj   +1 more source

Evaluation of the dose reduction effect of crystalline lens exposure in cone‐beam computed tomography with bismuth eye shield for image‐guided radiation therapy: An anthropomorphic phantom study

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract This study aimed to evaluate the dose‐exposure reduction effect of a crystalline lens with a bismuth eye shield using cone‐beam computed tomography (CBCT) for head image‐guided radiation therapy. The ocular surface dose of the head phantom (THRA‐1) is defined as a crystalline lens exposure dose and is measured using a radiophotoluminescence ...
Tatsuya Yoshida   +5 more
wiley   +1 more source

Nuclear Physics and Lattice QCD [PDF]

open access: yesPoS LAT2005 (2005) 020, 2005
Lattice QCD is progressing toward being able to impact our understanding of nuclei and nuclear processes. I discuss areas of nuclear physics that are becoming possible to explore with lattice QCD, the techniques that are currently available and the status of numerical explorations.
arxiv  

Feasibility study of skin dosimetry with TLD sheets for measuring the effect of 3D printed bolus in radiotherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract The thermoluminescence dosimeter (TLD) sheet is a measurement device coated with manganese‐doped LiB3O5 in sheet form. The sheet is 0.2‐mm thick and flexible. Hence, it can fit and be installed on irregular surfaces. The current study aimed to evaluate the feasibility of measuring patient surface doses during radiation therapy using TLD sheets.
Yuya Miyasaka   +8 more
wiley   +1 more source

Impact of enhanced leaf model on dose calculation accuracy in single‐isocenter multitarget stereotactic radiosurgery treatments

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Single‐isocenter multitarget (SIMT) radiosurgery has become increasingly popular as advancement in planning and delivery systems have made this approach clinically viable. With targets varying in size and distance from isocenter, SIMT plans are highly complex with dynamic multileaf collimator (MLC) motion.
Hem Moktan   +3 more
wiley   +1 more source

Dose rate correction of a diode array for universal wedge field dosimetric verification

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To study the performance of MapCHECK 3 (MC3) in measuring universal wedge fields and propose a dose rate correction strategy to improve MC3 measurement accuracy. Materials and methods Universal wedge fields with different wedge angles and field sizes were measured at different depths using MC3.
Linyi Shen   +6 more
wiley   +1 more source

Monte Carlo modeling of radiation dose from radiation therapy with superficial x‐rays

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Introduction Superficial x‐rays (50–100 kVp) are used for treating non‐melanoma skin cancer and intraoperative radiation therapy (IORT). At these energies, the photoelectric effect significantly increases absorbed dose to bone compared to soft tissue.
Reham Barghash   +3 more
wiley   +1 more source

Evaluation of dosimetric and spatial accuracy of a virtual cone technique for radiosurgery using linac‐integrated CBCT‐based polymer gel dosimetry

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study evaluates the dosimetric and geometric precision of a virtual cone technique using CBCT‐based polymer gel dosimetry, enabling radiation delivery, and imaging readout within an identical spatial coordinate system. Methods We created a C# script for a virtual cone technique that generates a treatment plan with 10 gantry arcs ...
Tenzin Kunkyab   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy