Results 91 to 100 of about 36,313 (321)

All-Sky Earth Occultation Observations with the Fermi Gamma Ray Burst Monitor [PDF]

open access: yesarXiv, 2009
Using the Gamma Ray Burst Monitor (GBM) on-board Fermi, we are monitoring the hard X-ray/soft gamma ray sky using the Earth occultation technique. Each time a source in our catalog enters or exits occultation by the Earth, we measure its flux using the change in count rates due to the occultation.
arxiv  

A digital video system for observing and recording occultations [PDF]

open access: yes, 2015
Stellar occultations by asteroids and outer solar system bodies can offer ground based observers with modest telescopes and camera equipment the opportunity to probe the shape, size, atmosphere and attendant moons or rings of these distant objects. The essential requirements of the camera and recording equipment are: good quantum efficiency and low ...
arxiv   +1 more source

Does dose calculation algorithm affect the dosimetric accuracy of synthetic CT for MR‐only radiotherapy planning in brain tumors?

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study compares the dosimetric accuracy of deep‐learning‐based MR synthetic CT (sCT) in brain radiotherapy between the Analytical Anisotropic Algorithm (AAA) and AcurosXB (AXB). Additionally, it proposes a novel metric to predict the dosimetric accuracy of sCT for individual post‐surgical brain cases.
Jeffrey C. F. Lui   +3 more
wiley   +1 more source

Automatic skin flash optimization in breast and chestwall VMAT with static angle modulated ports: Effect of HU and flash margin size on plan quality and robustness

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Skin flash is typically added to breast and chestwall plans to ensure robust target coverage in the presence of respiratory motion, anatomic changes, and small setup uncertainties. Adding skin flash in volumetric modulated arc therapy (VMAT) plans is an iterative and manual process.
Emily Hubley   +6 more
wiley   +1 more source

Data analysis of 2005 Regulus occultation and simulation of the 2014 occultation [PDF]

open access: yesarXiv, 2014
On March 20, 2014 at 6:06 UT (2:06 New York time) Regulus, the 1.3 magnitude brighter star of Leo constellation, is going to be occulted by the asteroid 163 Erigone. The unusual event, visible to the naked eye over NYC, can allow to measure the shape of the asteroid, with reaching a space resolution below the diffraction limit of the eye, and of all ...
arxiv  

Surveying by occultations

open access: yesThe Astronomical Journal, 1957
A method of surveying which uses data obtained from photoelectrically observed occultations is described. The method is applicable in those cases where it is desired to connect triangulation systems which are too widely separated to be tied together by the usual means. The discussion includes the prediction and reduction of occultations.
S. W. Henriksen   +3 more
openaire   +3 more sources

Assessing HyperSight iterative CBCT for dose calculation in online adaptive radiotherapy for pelvis and breast patients compared to synthetic CT

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose/objectives Recent technological advancements have increased efficiency for clinical deliverability of online‐adaptive‐radiotherapy (oART). Previous cone‐beam‐computed‐tomography (CBCT) generations lacked the ability to provide reliable Hounsfield‐units (HU), thus requiring oART workflows to rely on synthetic‐CT (sCT) images derived ...
Jingwei Duan   +7 more
wiley   +1 more source

Occult Macular Dystrophy

open access: yesTürk Oftalmoloji Dergisi, 2016
Occult macular dystrophy is an inherited macular dystrophy characterized by a progressive decline of bilateral visual acuity with normal fundus appearance, fluorescein angiogram and full-field electroretinogram. This case report presents a 20-year-old female patient with bilateral progressive decline of visual acuity for six years.
Serra Arf   +4 more
openaire   +3 more sources

Impact of enhanced leaf model on dose calculation accuracy in single‐isocenter multitarget stereotactic radiosurgery treatments

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Single‐isocenter multitarget (SIMT) radiosurgery has become increasingly popular as advancement in planning and delivery systems have made this approach clinically viable. With targets varying in size and distance from isocenter, SIMT plans are highly complex with dynamic multileaf collimator (MLC) motion.
Hem Moktan   +3 more
wiley   +1 more source

Analysis of GNSS radio occultation data from satellite ZH-01

open access: yesEarth and Planetary Physics, 2018
The electromagnetic satellite Zhangheng 01 (ZH-01) was successfully launched on February 2, 2018. The GNSS Radio Occultation (GRO) receiver on board the satellite is able to observe the occultation events of GPS and BeiDou navigation satellites.
Yan Cheng   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy