Results 291 to 300 of about 1,089,577 (427)

Log file‐based quality assurance method for respiratory gating system

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background As medical linear accelerator technology advances, enabling higher dose rate deliveries, hypofractionation regimens has increased. This necessitates respiratory gating systems that synchronize radiation delivery with tumor position, requiring simple rigorous quality assurance (QA) to ensure treatment accuracy and patient safety ...
Wonjoong Cheon   +7 more
wiley   +1 more source

DICOM attribute manipulation tool: Easily change frame of reference, series instance, and SOP instance UID

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose In radiation oncology, the integration and registration of multiple imaging modalities is a crucial aspect of the diagnosis and treatment planning process. These images are often inherently registered, a useful feature in most cases, but possibly a hindrance when registration modifications are required.
Brian M. Anderson, Casey Bojechko
wiley   +1 more source

Ocular hypertension [PDF]

open access: yesActa Ophthalmologica, 2013
Jost B. Jonas   +4 more
openaire   +3 more sources

Rinosporidiose ocular

open access: hybrid, 1956
José Lucas de Souza   +2 more
openalex   +2 more sources

An investigation into the feasibility and efficacy of stereotactic radiosurgery for 1–3 cm single brain lesions on the ring‐mounted Halcyon LINAC

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose An evaluation of the accuracy, safety, and efficiency of the Halcyon ring delivery system (RDS) for stereotactic radiosurgery (SRS) treatment to relatively small (1–3 cm) brain lesions. Methods After completing the extensive in‐house quality assurance checks including Winston–Lutz test and independent dose verification via MD Anderson ...
Kate Hazelwood   +5 more
wiley   +1 more source

Evaluating feature extraction reproducibility across image biomarker standardization initiative‐compliant radiomics platforms using a digital phantom

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The aim of this study was to thoroughly analyze the reproducibility of radiomics feature extraction across three Image Biomarker Standardization Initiative (IBSI)‐compliant platforms using a digital phantom for benchmarking. It uncovers high consistency among common features while also pointing out the necessity for standardization ...
Han‐Back Shin   +5 more
wiley   +1 more source