Results 51 to 60 of about 20,085 (220)

Effectiveness of an Eye-Cervical Re-Education Program in Chronic Neck Pain: A Randomized Clinical Trial [PDF]

open access: yes, 2020
Objectives. Proprioceptive training is popularly applied as a therapeutic exercise method in physiotherapy. Its effects on pain and range of motion are only poorly evaluated.
Chamorro-Moriana, Gema   +5 more
core   +1 more source

Dynamic contour tonometry versus Goldmann applanation tonometry: challenging the gold standard [PDF]

open access: yes, 2010
The accurate measurement of intraocular pressure (IOP) is fundamental to almost any ophthalmic examination. Dynamic contour tonometry (DCT) was introduced 5 years ago as an entirely novel contact tonometry principle designed to measure IOP largely ...
Bochmann, F, Kaufmann, C, Thiel, M A
core   +1 more source

Anestesia peribulbar com ropivacaína: estudo da ação vasoconstritora Anestesia peribulbar con ropivacaína: estudio de la acción vasoconstrictora Ropivacaine in peribulbar anesthesia: vasoconstrictive properties

open access: yesRevista Brasileira de Anestesiologia, 2010
JUSTIFICATIVA E OBJETIVOS: A anestesia peribulbar pode reduzir o fluxo sanguíneo ocular (FSO) por elevação da pressão intraocular (PIO) ou ação de fármacos.
Catia Sousa Govêia, Edno Magalhãe
doaj   +1 more source

The Effect of the Water Drinking Test on Ocular Parameters and Choroidal Thickness in Glaucoma Suspects

open access: yesMedicina, 2023
Background and objectives: We aimed to evaluate the effects of the water drinking test (WDT) on several systemic and ocular parameters, including choroidal thickness, which was assessed through optical coherence tomography angiography (OCTA), in glaucoma
Stylianos A Kandarakis   +8 more
doaj   +1 more source

Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry

open access: yesBMC Ophthalmology, 2004
Background The new Ocular Dynamic Contour Tonometer (DCT), investigational device supplied by SMT (Swiss Microtechnology AG, Switzerland) allows simultaneous recording of intraocular pressure (IOP) and ocular pulse amplitude (OPA). It was the aim of this
Grus Franz-H   +2 more
doaj   +1 more source

Synapse elimination and learning rules co-regulated by MHC class I H2-Db. [PDF]

open access: yes, 2014
The formation of precise connections between retina and lateral geniculate nucleus (LGN) involves the activity-dependent elimination of some synapses, with strengthening and retention of others. Here we show that the major histocompatibility complex (MHC)
Adelson, Jaimie   +7 more
core   +3 more sources

Ocular pulse amplitude after trabeculectomy [PDF]

open access: yes, 2018
Background: The ocular pulse amplitude (OPA) is the difference between the minimum and maximum values of the pulsatile intraocular pressure (IOP) wave contour. The OPA depends on ocular perfusion and IOP, which are both affected by a trabeculectomy (TE).
Bachmann, Lucas   +4 more
core  

The impact of central corneal thickness on values of intraocular pressure measured using two methods: Goldmann applanation and dynamic contour tonometry in patients with open-angle glaucoma [PDF]

open access: yesHalo 194, 2020
Introduction Dynamic contour tonometry (DCT) is a contact, non-applanation method for measuring intraocular pressure (IOP). Objektive The study aimed at evaluating the impact of central corneal thickness (CCT) on values of IOP measured using two methods:
Jordanova Elena   +5 more
doaj  

Measurement of Intraocular Pressure with Applanation, Dynamic Contour, and Air-Puff Tonometers: A Comparative Study in Primary Open-Angle Glaucoma and Healthy Cases

open access: yesBeyoglu Eye Journal, 2020
INTRODUCTION[|]This study aimed to investigate and compare the reliability of Goldmann applanation tonometer (GAT), dynamic contour (DCT), and noncontact (NCT) tonometers in intraocular pressure (IOP) measurement and the affecting parameters in healthy ...
Kemal Turgay Ozbilen, M. Selim Kocabora
doaj   +1 more source

Effects of phacoemulsification surgery on ocular hemodynamics [PDF]

open access: yesInternational Journal of Ophthalmology, 2013
AIM: To evaluate the possible effects of phacoemulsification cataract surgery on ocular hemodynamics.METHODS:In this prospective study, intraocular pressure (IOP), pulsatile ocular blood flow (POBF), and ocular pulse amplitude (OPA) were measured pre ...
Adem Turk   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy