Effect of mydriasis induced by topical 0.5% tropicamide instillation on the corneal biomechanical properties in healthy individuals measured by ocular response analyzer [PDF]

open access: yesCutaneous and Ocular Toxicology, 2015
Purpose: This observational study aims to investigate the effects of tropicamide (0.5%) on corneal biomechanical properties, with the ocular response analyzer (ORA), in healthy individuals. Methods: Corneal hysteresis (CH), corneal resistance factor (CRF)
Gulfidan Bitirgen   +2 more
exaly   +3 more sources

The effects of Valsalva manoeuvre on Ocular Response Analyzer measurements [PDF]

open access: yesAustralasian journal of optometry, The, 2015
Background: The aim was to evaluate the effects of the Valsalva manoeuvre on Ocular Response Analyzer (ORA) measurements. Methods: A total of 152 eyes of 76 healthy individuals were included.
Melis Palamar
exaly   +2 more sources

Comparison of ocular response analyzer, dynamic contour tonometer and Goldmann applanation tonometer [PDF]

open access: yesInternational Ophthalmology, 2010
The aim of this study was to compare the intra-ocular pressure (IOP) obtained by ocular response analyzer (ORA), dynamic contour tonometer (DCT) and Goldmann applanation tonometer (GAT). In 102 patients (47 with primary open-angle glaucoma and 55 healthy
Ingeborg Stalmans   +2 more
exaly   +2 more sources

Measuring corneal hysteresis: threshold estimation of the waveform score from the Ocular Response Analyzer [PDF]

open access: yesGraefe's Archive for Clinical and Experimental Ophthalmology, 2012
Background The aim of this study was to determine a threshold waveform score (WS) for the best score value (BSV) in the Ocular Response Analyzer (ORA). Methods Retrospective study. One hundred and thirty-three healthy adults were recruited.
Marcelo Ayala   +2 more
exaly   +2 more sources

A comparison of the NCT Reichert R7 with Goldmann applanation tonometry and the Reichert ocular response analyzer [PDF]

open access: yesOphthalmic and Physiological Optics, 2011
P>Purpose:The aim of this study was to evaluate the accuracy of intraocular pressure (IOP) values from the new non-contact tonometer (NCT) Reichert R7 by comparing results with those from Goldmann applanation tonometry (GAT) and the Reichert Ocular ...
JOSÉ M González-Méijome   +2 more
exaly   +3 more sources

Evaluation of the Intraocular Pressure Measured with the Ocular Response Analyzer [PDF]

open access: yesCurrent Eye Research, 2010
PURPOSE: Comparison of the magnitude and repeatability of the intraocular pressure (IOP) measured with the Ocular Response Analyzer (ORA) to that measured with the Goldmann tonometer. METHODS: Two sets of IOP measurements were made, for 89 eyes of eighty-
Kelechi Ogbuehi
exaly   +1 more source

Identification of Biomechanical Properties of the Cornea: The Ocular Response Analyzer

Current Eye Research, 2012
Eberhard Spoerl   +2 more
exaly  

Precision of Ocular Response Analyzer

Current Eye Research, 2012
Achim Langenbucher   +2 more
exaly  