Results 41 to 50 of about 2,631,068 (301)
Micro‐ and nanorobots for targeted thrombolysis. This perspective elaborates on the clinical indication of blood clot disorders and current limitations for treatment. As a novel, alternative solution, micro‐ and nanorobots can be used to treat and break down thrombi.
Joshua M. Mesfin +3 more
wiley +1 more source
Background Diffuse coronary artery spasm after coronary artery bypass grafting may cause disastrous circulatory collapse and death if not detected and managed promptly. Case presentation Four out of 387 patients who underwent uneventful off-pump coronary
Benson Abraham +2 more
doaj +1 more source
Intelligent Micro/Nanorobots for Targeted Interventional Therapy: From Bench to Clinic
Zirui Zhang et al. reviewed the application and challenges of mobile nanomachines in interventional therapy. By converting exogenous energy, including chemical, magnetic, optical, and ultrasonic sources, into mechanical forces, micro/nanorobots (MNRs) enable precise actuation at unprecedented scales. Evolving far beyond traditional drug delivery, these
Zirui Zhang +5 more
wiley +1 more source
Off pump coronary bypass grafting of the circumflex artery [PDF]
The circumflex artery is the most challenging vessel to be grafted off pump, since it requires lifting and rotating of the heart. A method of exposure and stabilisation of the circumflex during construction of the anastomosis is described. The technique, which is routinely used in our institution, is effective, simple and safe.
Pitsis, AA, Angelini, GD
openaire +2 more sources
Left Main Coronary Artery Disease: Current Treatment Options [PDF]
Significant left main coronary artery disease is defined as a greater than 50% angiographic narrowing of the vessel. In general, there are three options for the treatment of LMCA disease which include optimal medical therapy, percutaneous ...
Omer Tanyeli, Tanyeli, Omer
core +1 more source
Smart Nanotechnologies for Multimodal Neuromodulation and Brain Interfacing
Recent advances in smart nanotechnologies are expanding the toolbox for brain interfacing, from wireless neuromodulation and high‐resolution sensing to targeted delivery within the central nervous system. By combining responsive nanomaterials with bioinspired design, these platforms enable multimodal interactions with neurons and glia, while also ...
Tommaso Curiale +6 more
wiley +1 more source
Introduction : Two-staged hybrid coronary revascularization (HCR) is a novel procedure in selected patients with multivessel coronary artery disease. However, few studies are available on the mid-term or long-term outcomes of this 2-staged procedure as ...
Hang Yang +15 more
core +1 more source
MI/RI is a major clinical challenge with high morbidity and mortality. This study demonstrates that SR‐A3 expression is downregulated in MI/RI, and its deletion exacerbates damage via the USP18/ISG15/STING axis, revealing SR‐A3 as a potential therapeutic target.
Yufei Han +24 more
wiley +1 more source
Off-Pump CABG in a Patient with Dextrocardia Totalis: A Case Report [PDF]
Coronary revascularization in patients with dextrocardia is not a common clinical condition. There are very few cases of off-pump coronary artery bypass. A 64-year-old woman was admitted to a university hospital due to exertional chest pain.
Ali Dabbagh, Ali Asghar Bolourian
doaj +2 more sources
OBJECTIVES: The objective of this study was to apply a pharmacokinetics-pharmacodynamics approach to investigate the free propofol plasma levels in patients undergoing coronary artery bypass grafting under hypothermic conditions compared with the off ...
Carlos R. Silva-Filho +5 more
doaj +1 more source

