A Novel Curve Database for Moisture Evaluation of Transformer Oil-Immersed Cellulose Insulation Using FDS and Exponential Decay Model

open access: yesIEEE Access, 2020
In recent decades, moisture evaluation of transformer oil-immersed cellulose insulation has been widely studied by using the frequency domain spectroscopy (FDS) technique.
Jiefeng Liu   +4 more
doaj   +1 more source

Diagnosis of Oil Immersed Transformers by Colorimetry of Insulating Papers

open access: yesIEEJ Transactions on Power and Energy, 1992
AbstractPower transformers have been expected to work with safety and reliability over a period of more than 30 years. The life expectancy of transformers depends upon the degree of deterioration of insulating materials, particularly conductor insulating paper.
Tsuruo Yorozuya   +5 more
openaire   +2 more sources

Accurate Assessment of Moisture Content and Degree of Polymerization in Power Transformers via Dielectric Response Sensing

open access: yesSensors, 2023
Power transformers are essential apparatuses used to transfer electrical energy from one voltage-level circuit to another. For reliable systems, preventive maintenance of the transformers is required to ensure good services of all mechanical, electrical,
Anantawat Kunakorn   +4 more
doaj   +1 more source

Carbon footprint of oil-immersed transformers

open access: yesTransformers Magazine, 2023
Končar Distribution and Special Transformers, a company in Croatia, has recognized the importance of fighting climate change and reducing CO2 emissions. To quantify the environmental impact of their products, they have conducted carbon footprint studies based on the ISO 14067:2018 standard and used the life cycle assessment (LCA) method. The LCA covers
Kolarić, Ines, Šerkinić, Vlatka
openaire   +2 more sources

Increase of Static Electrification in an Aged Oil-Immersed Transformer

open access: yesIEEJ Transactions on Power and Energy, 2007
AbstractIncrease of static electrification activity and discharge generation was experienced during the service operation of an aged power transformer. The transformer oil had high sulfide and sulfoxide contents and was liable to show high ECT value after aging.
Kobayashi, Takayuki   +4 more
openaire   +2 more sources

Visual Localization of an Internal Inspection Robot for the Oil-Immersed Transformer

open access: yesJournal of Robotics, 2023
Aiming at the problem that the robot is difficult to locate in the oil-immersed transformer, a visual positioning of the robot is proposed for internal inspection. First, in order to solve the problem of blur, distortion, and low contrast of the image obtained by the camera in the deteriorated and discolored transformer oil, an image enhancement ...
Yingbin Feng, Yahui Kou, Yanju Liu
openaire   +2 more sources

Effect of different shapes of electrodes on bridging in contaminated transformer oil [PDF]

open access: yes, 2014
Contaminated transformer oil has been tested under non uniform electric fields and the effect of different electrode systems presented in this paper. Three different electric fields were examined i.e. DC, AC and DC biased AC.
Igor O. Golosnoy   +9 more
core   +1 more source

Analytical methods for assessing paper degradation In transformers [PDF]

open access: yes, 2006
Power transformers are essential equipments for distributing electricity. However, maintenance of these equipments is necessary to ensure long working life and to avoid catastrophic incidents.
Christofidis, Stavros
core   +7 more sources

Recovery Voltage Measurements of Oil-immersed Transformer

open access: yesTransactions on Electrical and Electronic Materials, 2006
One of the methods currently being investigated as a possible non-intrusive diagnostic tool for condition monitoring of power transformer and cable is the recovery voltage measurement, which will be improving the ability to detect the content of water concentration and the ageing process in the insulation system and may thus be an indicator of ...
Ming-Hua Li   +3 more
openaire   +2 more sources

Evaluation of Lightning Impulse Test by Frequency Response Analysis [PDF]

open access: yes, 2006
In this work are presented the basis for improving the interpretation of transformer lightning impulse test and the development of a graphical user interface system, which allows comparisons of time domain data and frequency response.
Jorge Ramirez   +3 more
core   +3 more sources