Results 131 to 140 of about 28,245 (221)

Multiscale Microscopy via Automation: Dual Magnification Environmental Scanning Electron Microscopy Imaging by Frame Alternation

open access: yesAdvanced Materials Technologies, EarlyView.
An automation interface for environmental scanning electron microscopy (ESEM) enables simultaneous, interlaced data sets via frame‐by‐frame parameter changes. Demonstrated on oscillatory hydrogen oxidation over cobalt (Co) foil, dual‐magnification imaging bridges mesoscopic to microscopic length scales, capturing alternating views of surface dynamics ...
Maurits Vuijk   +7 more
wiley   +1 more source

Comparative analysis of clearing methods for 3D imaging of the vasculature in mineralized mouse tissues. [PDF]

open access: yesiScience
Ishola AO   +7 more
europepmc   +1 more source

Graphene‐Interfaced Stretchable Sweat Patch for Multiplexed Electrochemical Monitoring of IL‐6, Glucose, and Calcium Ions

open access: yesAdvanced Materials Technologies, EarlyView.
Flexible sweat sensor patch integrating graphene‑interfaced gold microelectrodes functionalized with bio‑receptors and ion‑selective membrane, coupled with a capillary‑driven microfluidic layer and portable potentiostat electronics for multiplexed monitoring of inflammatory, metabolic, and electrolyte biomarkers in microliter sweat volumes.
Roomia Memon   +4 more
wiley   +1 more source

Integrated photonic 3D tensor processing engine. [PDF]

open access: yesLight Sci Appl
Wu Y   +6 more
europepmc   +1 more source

Buckling‐Driven Linearity in Flexible Capacitive Pressure Sensors Based on a Three‐Dimensional Dual‐Pore Polyurethane Structure

open access: yesAdvanced Materials Technologies, EarlyView.
A flexible pressure sensor utilizing a 3D dual‐pore polyurethane structure is developed to overcome the intrinsic trade‐off between sensitivity and linearity. By inducing sequential buckling through distinct pore sizes and shapes, the device achieves highly linear and sensitive responses across a wide pressure range.
Jae Yeong Jang, Jaemin Choi, Young Jung
wiley   +1 more source

Deep-learning endomicroscope with large field-of-view and depth-of-field for real-time in vivo imaging of epithelial cancer hallmarks. [PDF]

open access: yesProc Natl Acad Sci U S A
Hou H   +15 more
europepmc   +1 more source

Flexible Pressure Sensor With Co‐Optimized Sensitivity and Linearity Based on Gradient Toroidal Microstructures

open access: yesAdvanced Materials Technologies, EarlyView.
A flexible piezoresistive pressure sensor with gradient toroidal CNT/PDMS microstructures is reported. The hierarchical geometry enables sequential electrode contact, achieving a sensitivity of 256.20 kPa−1 and linear response (R2 = 0.99) over 0–1000 kPa.
Rongmei Wang   +8 more
wiley   +1 more source

<i>In vivo</i> photoacoustic imaging of swine ureters injected with methylene blue. [PDF]

open access: yesJ Biomed Opt
Arroyo J   +7 more
europepmc   +1 more source

Solid Particle‐Liquid Metal Mixtures for Robust High‐Current Interconnects in Stretchable Electronics and Soft Robotics

open access: yesAdvanced Materials Technologies, EarlyView.
Metallic microparticles dispersed in liquid metal interconnects mitigate electromigration‐induced failure by reconfiguring internal current density distributions. These fillers facilitate the growth of a robust, protective gallium oxide shell at elevated temperatures, shifting the failure threshold toward a thermal limit.
Ethan J. Krings   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy