Results 11 to 20 of about 4,078,568 (242)

Fibre optic fizeau intererometer for optical coherence tomography [PDF]

open access: yes, 2006
The aim of the project was to develop the Fizeau interferometer configuration to take advantage of the benefits derived from its “downlead insensitivity” to temperature and polarisation fading.
Casaubieilh, P.
core   +7 more sources

Tissue surface as the reference arm in Fourier domain optical coherence tomography [PDF]

open access: yes, 2012
We present a simple method applicable to common-path Fourier domain optical coherence tomography (OCT) in which the tissue surface is used as the reference arm.
Giardini, Mario Ettore   +8 more
core   +5 more sources

Optical coherence tomography and scanning laser ophthalmoscopy: Approaches to dual-channel retinal tissue imaging [PDF]

open access: yes, 2014
We report a Talbot bands-based optical coherence tomography (OCT) system capable of producing longitudinal B-scan OCT images and en-face scanning laser ophthalmoscopy (SLO) images of the human retina in-vivo, with various degrees of ...
Adrian Bradu   +5 more
core   +1 more source

Phantoms for performance assessment of optical coherence tomography systems [PDF]

open access: yes, 2012
In this paper, we describe the procedures to make epoxy resin and agarose phantoms designed using Mie scattering calculations. The phantoms are constructed to be used in the estimation of point spread function (PSF) of an optical coherence tomography ...
S. A. Hojjatoleslami   +16 more
core   +1 more source

SVM-based texture classification in optical coherence tomography [PDF]

open access: yes, 2013
This paper describes a new method for automated textureclassification for glaucoma detection using high resolutionretinal Optical Coherence Tomography (OCT). OCT is anon-invasive technique that produces cross-sectional imageryof ocular tissue.
Alin Achim   +9 more
core   +1 more source

Characterization of optical fiber imaging bundles for swept-source optical coherence tomography [PDF]

open access: yes, 2011
Fiber imaging bundles have been investigated for use in endoscopic optical coherence tomography (OCT) systems, to obviate the requirement for scanning components within the endoscope probe section.
Helen D. Ford   +3 more
core   +1 more source

Optical Coherence Tomography (OCT)

open access: yes, 2020
Optical coherence tomography (OCT) is an imaging technic that was first applied for eye length measurements in 1988 and then in 1991 for creating in vivo retinal images. During ensuing years, it became an essential part of ocular examination in most eye clinics.
Fedra Hajizadeh, Mohammad Zarei
openaire   +3 more sources

Special Feature Development and Application of Optical Coherence Tomography (OCT)

open access: yesApplied Sciences, 2017
To celebrate the 25th anniversary of the introduction of OCT, the special feature issue entitled “Development and Application of Optical Coherence Tomography (OCT)” had been initiated [...]
Michael Pircher
doaj   +1 more source

Morphological characterization of subretinal hyper-reflective material in posterior uveitis using swept-source optical coherence tomography and optical coherence tomography angiography

open access: yesIndian Journal of Ophthalmology, 2022
Purpose: To analyze the structural features of subretinal hyper-reflective material (SHRM) in posterior uveitis using swept-source optical coherence tomography (SS-OCT) and optical coherence tomography angiography (SS-OCTA).
Atul Arora   +7 more
doaj   +1 more source

Surface imaging of metallic material fractures using optical coherence tomography [PDF]

open access: yes, 2014
We demonstrate the capability of optical coherence tomography (OCT) to perform topography of metallic surfaces after being subjected to ductile or brittle fracturing.
Demian, D.   +4 more
core   +1 more source