Results 231 to 240 of about 18,411,493 (260)

Exploring surface‐guided systems for intelligent breathing‐adapted four‐dimensional computed tomography: A comparison to infrared‐based reflective marker systems

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study evaluates the technical feasibility of adapting a surface monitoring system, designed for conventional four‐dimensional computed tomography (4DCT), to an intelligent, breathing‐adapted 4DCT and examines its potential to expand the currently limited range of supported surrogate systems.
Niklas Lackner   +4 more
wiley   +1 more source

Characterization of a prototype rapid kilovoltage x‐ray image guidance system designed for a linear accelerator radiation therapy unit

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study evaluates a novel cone‐beam computed tomography (CBCT) imaging solution integrated onto a conventional C‐arm linear accelerator (linac) with increased gantry speed. The purpose is to assess the impact of improved imaging hardware and reconstruction algorithms on image quality.
Theodore Arsenault   +9 more
wiley   +1 more source

Practical experience in commissioning ring applicators using ring applicator component type with bravos control software v1.2

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The Bravos v1.2 control software introduces a ring applicator component type (ACT) with channel length verification to address geometric characteristics and dosimetric discrepancies caused by source positioning inaccuracies. This study aims to commission the ring applicator and investigate the new ring ACT in Bravos 1.2.
Xiuxiu He   +4 more
wiley   +1 more source

Stereotactic radiosurgery for multiple small brain metastases using gamma knife versus single‐isocenter VMAT: Normal brain dose based on lesion number and size

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The study evaluates rapid linear accelerator (Linac) single isocenter stereotactic radiosurgery (SRS) with Hyperarc for large target numbers. We compared to Gamma Knife (GK), which suffers from long treatment times and investigated causes of differences. Methods Linac SRS and GK treatment plans for patients receiving 18 Gy to the gross
Abram Abdou   +4 more
wiley   +1 more source

Geometric and dosimetric evaluation of a commercial AI auto‐contouring tool on multiple anatomical sites in CT scans

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Current radiotherapy practices rely on manual contouring of CT scans, which is time‐consuming, prone to variability, and requires highly trained experts. There is a need for more efficient and consistent contouring methods. This study evaluated the performance of the Varian Ethos AI auto‐contouring tool to assess its potential integration into
Robert N. Finnegan   +6 more
wiley   +1 more source

Dosimetric effect of silicone‐based gel on skin surface during volumetric modulated arc therapy for breast cancer

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to quantify and compare the dosimetric effects of varying thicknesses of StrataXRT, a silicone‐based gel, and other topical agents on the skin surface during volumetric modulated arc therapy (VMAT) for breast cancer.
Tenyoh Suzuki   +13 more
wiley   +1 more source

Development of a generic focal spot measurement method suitable for bore‐type linacs

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose In linear accelerators, deviations in the x‐ray focal spot position significantly affect the accuracy of radiation therapy. However, as the focal spot position in bore‐type linac systems such as the Radixact system, cannot be assessed using conventional methods, a new evaluation method is required.
Hidetoshi Shimizu   +5 more
wiley   +1 more source

A method for measuring spatial resolution based on clinical chest CT sequence images

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aimed to develop and validate a method for characterizing the spatial resolution of clinical chest computed tomography (CT) sequence images. Methods An algorithm for characterizing spatial resolution based on clinical chest CT sequence images was developed in Matlab (2021b).
Ying Liu   +3 more
wiley   +1 more source

Position‐dependent offset corrections for ring applicator reconstruction in cervical cancer brachytherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Due to the tight curvature in their design, ring applicators are usually associated with large positioning errors. The standard practice to correct for these deviations based on global offsets may not be sufficient to comply with the recommended tolerance.
Leon G. Aldrovandi   +3 more
wiley   +1 more source

acados—a modular open-source framework for fast embedded optimal control

Mathematical Programming Computation, 2019
This paper presents the acados software package, a collection of solvers for fast embedded optimization intended for fast embedded applications. Its interfaces to higher-level languages make it useful for quickly designing an optimization-based control ...
Robin Verschueren   +9 more
semanticscholar   +1 more source

Home - About - Disclaimer - Privacy