Results 141 to 150 of about 5,284 (179)
Some of the next articles are maybe not open access.

The acceleration-oscillogram method of motor-torque measurement

Electrical Engineering, 1942
The need for an improved method of measuring starting torque of large induction starting synchronous motors as compared to the power input and dynamometer methods, has led to the use of the acceleration oscillogram. A low ripple, permanent magnet type d-c generator is driven by the motor, and traces a time-speed oscillogram, from which acceleration ...
C. R. Atkinson, E. G. Downie
openaire   +2 more sources

Wavelet frequency spectrum analysis of oscillograms

The Analyst, 1999
By combining wavelet transform with frequency spectrum analysis, wavelet frequency spectrum analysis of an oscillogram was achieved, based on the wavelet property of extracting useful information. Compared with Fourier frequency spectrum analysis of an oscillogram, this method presents many advantages.
Jianbin Zheng   +3 more
openaire   +1 more source

Interpretation of the Speech Oscillogram

The Journal of the Acoustical Society of America, 1966
Due to the dynamic nature of sound, it is difficult to observe speech characteristics quantitatively by ear and make precise reproducible measurements unless of a rather coarse nature. However, we can stop the motion and obtain static measurable elements by taking pictures of the sound waves.
Homer Dudley, Everett Aho
openaire   +1 more source

Analysis of Short-Circuit Oscillograms

Transactions of the American Institute of Electrical Engineers, 1941
METHODS of analyzing the oscillograms of short circuit currents of synchronous machines, in accordance with the two reaction theory, are presented in this paper. Differences between the results found here and the more generally accepted equations, based on symmetrical components, are pointed out.
openaire   +2 more sources

Clinical investigation by the oscillogram of peripheral arteries

American Heart Journal, 1955
Abstract An analysis of the oscillograms (tracings of arterial oscillations) of the extremities of 127 subjects, both normal and diseased, is presented. Tracings were made with a specially constructed differential manometer based on the principles of the torsion-tension relationship of a twisted metal band, and utilizing an ordinary blood pressure ...
M G, KETTNER, C, FERRERO, P W, DUCHOSAL
openaire   +2 more sources

Breaker performance studied by cathode ray oscillograms

Electrical Engineering, 1935
Analyses of cathode ray oscillograms of circuit interruptions reveal characteristics of the circuits that are significant in the study of circuit breaker performance. While a complete analysis of such an oscillogram involves much detailed work, the study of several typical oscillograms reveals the significance of certain types of voltage variations and
openaire   +1 more source

Photoelectric Comparator for Measuring Oscillograms

Review of Scientific Instruments, 1954
A device for measuring photographic oscillogram coordinates is described. By means of a photoelectric balancing technique the instrument allows the locating of the ``middle'' of a photographic line with an error of the order of a few microns. The ``middle'' of a line is defined by the instrument as being the point of equal transmission, which is the ...
openaire   +1 more source

Measuring air flows with recording on an oscillogram

Measurement Techniques, 1974
1. Recording of air (gas) flow measurements by means of an oscillograph provides higher precision than visual reading and accelerates the testing process. 2. In servicing complicated systems with a large number of instruments, the above method is more economical and simple. 3.
I. N. Khramov, V. N. Khramov
openaire   +1 more source

Large Picture Projection of Oscillograms

1965
The surface area of the fluorescent screen of the normal 10 cm or 13 cm diameter cathode ray tubes, is adequate for the saticfactory display of all ordinary oscillograms; indeed it is for this reason that the 10 cm and 13 cm dimensions have been selected and more or less standardized. Even fine details can be observed at normal reading distance without
openaire   +1 more source

Test Method for Fault Insertion-Based Oscillogram Analysis Systems

Приборы и системы. Управление, контроль, диагностика, 2021
На основе анализа процесса проектирования и производства осциллографических систем (ОС), включающих системы анализа осциллограмм периодических электрических сигналов (САОПЭС), сформулирована проблема необходимости сокращения материальных и временных затрат на этап их испытаний при одновременном сохранении качества производимых ОС. Цель.