Results 111 to 120 of about 20,888 (181)
In MOCVD MoS2 memristors, a current compliance‐regulated Ag filament mechanism is revealed. The filament ruptures spontaneously during volatile switching, while subsequent growth proceeds vertically through the MoS2 layers and then laterally along the van der Waals gaps during nonvolatile switching.
Yuan Fa +19 more
wiley +1 more source
ABSTRACT Chitosan, a polysaccharide upcycled from biowaste, has long promised sustainable, biocompatible, and antimicrobial films and devices, an appeal reinforced by its recent regulatory recognition, with several chitosan‐based antibacterial dressings gaining clearance through the Food and Drug Administration's 510(k) pathway.
Jacopo Nicoletti +16 more
wiley +1 more source
Numerical investigation on the mechanical response of steel-frame polyethylene pipelines subjected to strike-slip faulting. [PDF]
Zhu Z, Huang X.
europepmc +1 more source
Optoelectronic synaptic devices based on solution‐processed molecular telluride GST‐225 phase‐change inks are demonstrated for three‐factor learning. A global optical signal broadcast through a silicon waveguide induces non‐volatile conductance updates exclusively in locally electrically flagged memristors.
Kevin Portner +14 more
wiley +1 more source
Perspective on the paper: GDR MiDi. On dense granular flows. [PDF]
Herrmann HJ, Luding S.
europepmc +1 more source
ABSTRACT Electronic waste has emerged as a major environmental challenge, driven by the massive consumption and a limited lifetime of modern electronic devices, stimulating the development of sustainable electronics. Here, an all‐biomaterial gelatin‐choline‐citric acid ([Ch][CA]) ionogel is developed as an active binder to realize self‐sintered ...
Lin Guo +10 more
wiley +1 more source
High-precision stress prediction using deep energy network enhanced by stress equilibrium with Delaunay integration on refined grid. [PDF]
Ye Y, An D, Li H, Wang W, Li X, Shi P.
europepmc +1 more source
A soft, dual‐channel hydrogel patch enables simultaneous detection of wound temperature and strain by integrating ion‐diffusion‐mediated thermoelectric and resistive sensing. The conformal design maintains stable performance during motion, capturing subtle inflammatory and mechanical changes for continuous wound monitoring.
Yu Fang +7 more
wiley +1 more source
Numerical analysis of three-dimensional middle ear and inner ear based on nonlinear and viscoelastic constitutive relations. [PDF]
Yao W, Wang J, Ye J.
europepmc +1 more source

