Results 141 to 150 of about 14,391 (289)

Towards practical oscillation detection in wind farms: Comparative study of AI models, novel metrics, and edge implementations

open access: yesEnergy Conversion and Economics, EarlyView.
Abstract Fast oscillations observed in wind farms and other renewable energy systems interfaced with power grids must be addressed promptly to prevent devastating shutdown and damage. Existing approaches mainly target high‐magnitude oscillations using data‐intensive convolutional neural networks (CNNs), leading to delayed detection and overlooking mild
Shyam Yathirajam   +8 more
wiley   +1 more source

Full‐stage risk management of forecast deviation for large‐scale renewable energy participating in the spot market

open access: yesEnergy Conversion and Economics, EarlyView.
Abstract Against the backdrop of renewable energy achieving full market integration, renewable energy forecasting deviations have become a critical bottleneck constraining the clearing efficiency of electricity spot markets, hindering the rational allocation of costs, and threatening the secure operation of the power system.
Sicheng Xu   +5 more
wiley   +1 more source

Outage performance of dual-hop fading relay channels

open access: yes, 2013
Unlike wire-line networks, one primary challenge in wireless communication is the existence of fading, which may significantly attenuate the signal power seen at the receiver. This adverse effect of fading can be combated by using diversity techniques to
Liu, Ying
core  

Investigating Breathing Dynamics of a 110 kV Oil‐Immersed Transformer Using Thermal‐Fluid‐Structure Interaction Modelling

open access: yesHigh Voltage, EarlyView.
ABSTRACT The breathing system of an oil‐immersed transformer is of vital importance for maintaining equilibrium between internal and external pressures, with any malfunction potentially disrupting the transformer's stable operation. This study develops a thermal–fluid–structure interaction (TFSI) model to simulate the breathing phenomenon in a 110 kV ...
Lujia Wang   +5 more
wiley   +1 more source

Low‐Frequency Oscillation Suppression of FDR Time‐Domain Diagnostic Waveforms for Cable Defects Based on Splicing Technology

open access: yesHigh Voltage, EarlyView.
ABSTRACT A time domain pulse (TDP) based on the frequency domain reflectometry (FDR) method can be used to diagnose the insulation state of cable defects. However, because of the limitations of the FDR test instrument, the lack of a reflection coefficient spectrum (RCS) in the low‐frequency band (LFB) can result in low frequency oscillation in the time
Jingtao Huang   +6 more
wiley   +1 more source

Construction and Application of Online Vibration Frequency Response Analysis Method for Converter Transformer Winding

open access: yesHigh Voltage, EarlyView.
ABSTRACT The harmonic current and vibration of a converter transformer are effective pieces of information for detecting mechanical faults in the winding. In this paper, the ratio of vibration acceleration to the current squared is defined as the vibration frequency response function (VFRF) of the winding, and then, a novel online vibration frequency ...
Shuyu Wu, Fan Zhang, Shengchang Ji
wiley   +1 more source

Regional Infrared and Visible Image Registration for Distribution Substation Areas With Wide Depth of Field

open access: yesHigh Voltage, EarlyView.
ABSTRACT Infrared and visible image registration is a key task in automated distribution network inspection. Previous approaches typically apply a single homography to align infrared and visible images leading to local misalignment. To address this, this study proposes a novel region‐based registration algorithm specifically designed for wide‐depth ...
Yingchen Zhang, Bo Wang, Fei Tang
wiley   +1 more source

Influence of Arc Faults on Pressure Production Characteristics in AC Turret of UHV Transformers

open access: yesHigh Voltage, EarlyView.
ABSTRACT The overpressure caused by arc fault in the oil tank can lead to a transformer explosion. Since the AC turret of transformers serves to connect the transformer windings with the AC busbar, the arc current can be extremely high if an earth fault arc occurs leading to potentially hazardous pressure.
Yuhang Li   +4 more
wiley   +1 more source